Specifications
Model
Fre-
quen-
cy
(Hz)
Belt
Ten-
sion
(lbs.)
Ten-
sion
Gau
ge
(N)
130-160 52 ± 2 214 ±
16
954 ±
72
Table 35
• Spring Length. Tighten eyebolt top nut until the
spring measures 4 3/4 inches, (45-65 pound models) or
4 inches (85-160 pound models) between the hooks.
Torque jam nut to spring bracket to 20.6 ± 2 ft.-lbs.
Refer to Figure 42 .
• Maintain Tension During Belt Removal. If propor
tension is achieved, tape the jam nut in place and loos-
en eyebolt top nut to release the belt. Replace belt and
retighten eyebolt top nut back to jam nut position. Re-
fer to Figure 42 .
c. Verify that V-belts are properly aligned by checking pul-
ley alignment. On 45-105 pound models the motor pulley
should align with end of motor shaft to align belts. On
130-165 pound models, slide the motor pulley along the
motor shaft and secure once belt alignment on the sheave
is attained.
1. Install belt on basket sheave.
2. Install belt on motor pulley.
3. Insert belt in appropriate motor pulley grooves so belt
rides on the center of the basket sheave.
4. Check overflow hose and drain hose for leaks or visible signs
of deterioration. Replace immediately if either are present.
5. Clean inlet hose filter screens:
a. Turn water off and allow valve to cool, if necessary.
b. Unscrew inlet hose and remove filter screen.
c. Clean with soapy water and reinstall. Replace if worn or
damaged.
6. Tighten anchor bolts, if necessary.
7. Use a vacuum to clean lint from motor.
8. Clean interior of machine, by wiping with a water-soaked
sponge or cloth. Use compressed air to clear debris between
the shell and the basket by directing it through the perfora-
tions of the basket.
9. Use compressed air to ensure that all electrical components
are free of moisture and dust.
10. Remove chemical supply components and check all flush ho-
ses and connections for residual chemicals, leaks or visible
signs of deterioration. Clean or replace as necessary.
11. If applicable, check the supply dispenser hoses and hose con-
nections for leaks or visible signs of deterioration. Replace
immediately if either are present.
12. Verify points of contact at terminals and quick disconnects
are firm trhoughout the machine by gently tugging the wires.
Reseat any loose contacts.
Quarterly
NOTE: Disconnect power to the machine before per-
forming the quarterly maintenance procedures.
1. Tighten door hinges and fasteners, if necessary.
2. Tighten anchor bolts, if necessary.
3. Tighten motor mounting bolt locknuts and bearing bolt lock-
nuts, if necessary.
4. Verify that the drain motor shield is in place and secure.
5. Check all painted surfaces for bare metal.
• If bare metal is showing, paint with primer or solvent-
based paint.
• If rust appears, remove it with sandpaper or by chemical
means. Then paint with primer or solvent-based paint.
6. Clean steam filter, where applicable.
a. Turn off steam supply and allow time for the valve to
cool.
b. Unscrew nut.
c. Remove element and clean.
d. Replace element and nut.
7. Check the bearing mounting bolts to make sure they are tor-
qued to 357 ± 35 ft-lbs.
8. Place a large magnet over the normally-closed ball switch to
verify the stability switch operation.
Maintenance
F8410701ENR10
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 69