Specifications
5. Before operating machine, confirm lid is completely closed. Do not attempt to make chemical injection electrical connections
to points other than those provided specifically for that purpose
by the factory.
PHM940N_SVG
4
3
2
1
* Use a check valve on the end of tubing
† Must be mounted below the injection point
1. Injection Point*
2. Loops
3. Chemical Dispenser Pumb Outlet †
4. PVC Pipe
Figure 24
External Supplies
For proper communication between the machine and an external
chemical supply system, it is important for the low-voltage signal
power to be connected properly. The included wiring diagram
shows several different options for safe and correct wiring of this
interface.
The preferred method for connecting the wiring from the external
chemical supply system to the machine is to use the 300mA pow-
er of the machine’s 24VAC control transformer, which is inten-
ded strictly for this purpose. Other voltage and current options
are available, but require some wiring changes and must be pro-
vided with an external power source. Under no circumstances
should the high-voltage machine supply connections or source be
used for the communication wiring.
Communication wiring connections, which include a single row
of identified terminal blocks, can be found under a service panel
at the upper back of the machine.
Chemical Injection Using Internal 24VAC Control
Transformer
NOTE: Using the Internal 24VAC 300 Milliamp Control
Transformer is recommended by Alliance Laundry Sys-
tems.
IMPORTANT: DO NOT remove the red jumper wire from
the terminal strip.
There are 3 terminals necessary for this connection option.
• Terminal “24VAC COM” is used to connect one side of the
internal control transformer to the external dispenser input
signals common.
• The second terminal is used to connect the other side of the
control transformer to the machine output signals common
through a red jumper wire between “24VAC” and “RELAY
COM”. Refer to Figure 25 .
IMPORTANT: Do not use the transformer terminals if
an external power supply is used.
Specifications and Dimensions
56
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT F8410701ENR10