Specifications
CE Approval
Machines can be converted for lower voltage operation and/or 50
Hz operation. Refer to conversion label by nameplate for details.
45 Pound Capacity Models - CE Approval
Voltage Designation Specifications
Code Voltage Cycle Phase Wire
Full
Load
Amps
Circuit
Break-
er mm2
L-Speed Models
X 200–240 50/60 1/3 2/3 11/7 16/10 2.5
M-Speed Models
X 200–240 50/60 1/3 2/3 11/8 16/10 2.5
Q 220–240 50/60 3 3 71 80 25
N Standard 440-480 50/60 3 3 7 10 2.5
Electric Heat 36 40 10
P Standard 380-415 50/60 3 3 7 10 2.5
Electric Heat 32 40 10
V-Speed Models
X 200–240 50/60 1/3 2/3 17/11 20/16 2.5
Q Standard 220–240 50/60 3 3 11 16 2.5
Electric Heat 71 80 25
N Standard 440-480 50/60 3 3 7 10 2.5
Electric Heat 36 40 10
P Standard 380-415 50/60 3 3 7 10 2.5
Electric Heat 32 40 4
Wire sizing listed in this table is based on Article 310, Table 310.16 of the NEC; at 104°F [40°C] ambient temperature. Follow your
local electrical codes. Use only copper conductors, rated for 194ºF [90°C] or higher, type THHN or better. No more than three cur-
rent carrying conductors per raceway. Contact your local Authority having jurisdiction if you have questions. Circuit breakers should
be UL 489 listed or better. Single phase circuit breakers for single phase machines only; three phase circuit breakers for all others.
Table 26
Specifications and Dimensions
F8410701ENR10
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 47