Specifications
160 Pound Capacity Models - North American Approval
Voltage Designation Specifications
Codes Voltage Cycle Phase Wire
Full
Load
Amps
Circuit
Break-
er *AWG *mm2
V-Speed Models
Q 200–240 50/60 3 3 22 30 10 6
N 440–480 50/60 3 3 12 15 14 2.5
P 380–415 50/60 3 3 12 15 14 2.5
Wire sizing listed in this table is based on Article 310, Table 310.16 of the NEC; at 104°F [40°C] ambient temperature. Follow your
local electrical codes. Use only copper conductors, rated for 194ºF [90°C] or higher, type THHN or better. No more than three cur-
rent carrying conductors per raceway. Contact your local Authority having jurisdiction if you have questions. Circuit breakers should
be UL 489 listed or better. Single phase circuit breakers for single phase machines only; three phase circuit breakers for all others.
Table 25
Specifications and Dimensions
46
©