Specifications
85 Pound Capacity Models - North American Approval
Voltage Designation Specifications
Codes Voltage Cycle Phase Wire
Full
Load
Amps
Circuit
Break-
er *AWG *mm2
M-Speed
Q Standard 220–240 50/60 3 3 14 20 12 4
Electric
Heat
105 110 2 35
N Standard 440–480 50/60 3 3 9 15 14 2.5
Electric
Heat
39 40 8 10
P Standard 380–415 50/60 3 3 9 15 14 2.5
Electric
Heat
35 40 8 10
V-Speed Models
Q Standard 200–240 50/60 3 3 16 20 12 4
Electric
Heat
105 110 2 35
N Standard 440–480 50/60 3 3 10 15 14 2.5
Electric
Heat
39 40 8 10
P Standard 380–415 50/60 3 3 10 15 14 2.5
Electric
Heat
35 40 8 10
Wire sizing listed in this table is based on Article 310, Table 310.16 of the NEC; at 104°F [40°C] ambient temperature. Follow your
local electrical codes. Use only copper conductors, rated for 194ºF [90°C] or higher, type THHN or better. No more than three cur-
rent carrying conductors per raceway. Contact your local Authority having jurisdiction if you have questions. Circuit breakers should
be UL 489 listed or better. Single phase circuit breakers for single phase machines only; three phase circuit breakers for all others.
Table 22
Specifications and Dimensions
F8410701ENR10
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 43