Specifications

Electrical Installation Requirements
IMPORTANT: Electrical ratings are subject to change.
Refer to serial decal for electrical ratings information
specific to your machine.
DANGER
Electrical shock hazard will result in death or serious
injury. Disconnect electric power and wait five (5) mi-
nutes before servicing.
W810
WARNING
Dangerous voltages are present inside the machine.
Only qualified personnel should attempt adjustments
and troubleshooting. Disconnect power from the ma-
chine before removing any cover and guards, and
before attempting any service procedures.
W736
WARNING
Hazardous Voltage. Can cause shock, burn or death.
Verify that a ground wire from a proven earth ground
is connected to the lug near the input power block
on this machine.
W360
Electrical connections are made at the rear of the machine. The
machine must be connected to the proper electrical supply shown
on the identification plate attached to the rear of the machine, us-
ing copper conductors only.
IMPORTANT: Alliance Laundry Systems warranty does
not cover components that fail as a result of improper
input voltage.
Make sure the correct transformer jumper (208 Volt or 240 Volt)
is in place. Refer to the “optional” Electrical Service Conversion
label located on the back of the machine near the electrical serv-
ice input for machine electrical requirements.
AC inverter drives require a clean power supply free from volt-
age spikes and surges. Use voltage monitor to check incoming
power.
The following conditions require corrective action, contact the lo-
cal utility to adjust the voltage.
If the local utility cannot adjust the input voltage, install a
buckboost transformer to lower the input voltage.
Input voltage is above 240V or 480V, phase to ground voltage
exceeds 125% of normal line to line voltage, or 240V open
delta configuration (stinger leg). Contact the distributor or the
manufacturer for assistance.
On variable-speed models, the inverter drive provides thermal
overload protection for the drive motor. However, a separate
three-phase circuit breaker must be installed for complete electri-
cal overload protection. This prevents damage to the motor by
disconnecting all legs if one should be lost accidentally. Check
the nameplate on the back of the machine for recommended cir-
cuit breaker requirements size.
IMPORTANT: Do NOT use fuses in place of a circuit
breaker.
CAUTION
Do not use a phase adder on any variable-speed ma-
chine.
SW037
The machine should be connected to an individual branch circuit
not shared with lighting or other equipment.
The connection should be shielded in a liquid-tight or approved
flexible conduit with proper conductors of correct size installed
in accordance with the National Electric Code or other applicable
codes. The connection must be made by a qualified electrician
using the wiring diagram provided with the machine, or accord-
ing to accepted European standards for equipment labeled with
the CE mark.
Refer to serial plate for recommended circuit breaker size and de-
termine wire size based on local code requirements.
Refer to serial plate for recommended circuit breaker size and de-
termine wire sizes for runs up to 50 feet [15.24 meters]. Use next
larger size for runs of 50 to 100 feet [15.24 to 30.48 meters]. Use
2 sizes larger for runs greater than 100 feet [30.48 meters].
For personal safety and for proper operation, the machine must
be grounded in accordance with state and local codes. If such co-
des are not available, grounding must conform with the National
Electric Code, article 250 [current edition] or accepted European
standards for equipment labeled with the CE mark. The ground
connection must be made to a proven earth ground, not to conduit
or water pipes. Refer to Figure 19 and Figure 20 .
WARNING
Electrically heated machines DO NOT require dual
power sources. Do not connect customer power or
customer load to the Internal Load Distribution ter-
minal block. Refer to the machine electrical schemat-
ic for details.
W759
Specifications and Dimensions
F8410701ENR10
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 39