Specifications
Water Connection
Connections should be supplied by hot and cold water lines of at
least the sizes shown in the Water Supply Line Sizing table. In-
stallation of additional machines will require proportionately
larger water lines. Refer to Table 19 .
WARNING
To prevent personal injury, avoid contact with inlet
water temperatures higher than 125° Fahrenheit [51°
Celsius] and hot surfaces.
W748
Maximum water inlet temperature is 190 °Fahrenheit [ 88 °Cel-
sius].
Water Supply Information
Specifications 45-65 85-105 130-160
Number of main fill water inlets 2 2 2
Main fill and spray rinse (UniLinc only) inlet size
at machine, in. [mm]
3/4 [19] 3/4 [19] 1 [25]
End of factory supplied
hose
Size, in. [mm] 3/4 [19] 3/4 [19] 1 [25]
Thread Pitch, GHT
[BSPP]
3/4 x 11.5 [3/4 x 14] 3/4 x 11.5 [3/4 x 14] 1 x 11.5 [1 x 14]
Number of spray rinse water inlets (UniLinc only) 2 2 2
Spray rinse water inlet size (UniLinc only), in.
[mm]
3/4 [19] 3/4 [19] 3/4 [19]
Required pressure, (min. - max. psi [bar]) 20 – 85 [1.4 – 5.7] 30 - 85 [2 - 5.7] 30 - 85 [2 - 5.7]
Inlet flow capacity for main fill (warm fill at 85 psi,
both inlet valves open), gal/min [l/min]
45 [170] 45 [118] 54 [204]
Inlet flow capacity for spray rinse (warm fill at 85
psi, both inlet valves open), gal/min [l/min]
22 [83] 22 [83] 22 [83]
Table 18
To connect water service to machine with rubber hoses, use the
following procedure:
1. Before installing hoses, flush the water system for at least two
minutes.
2. Check filters in the machine’s inlet hoses for proper fit and
cleanliness before connecting.
3. Hang the hoses in a large loop; do not allow them to kink.
If additional hose lengths are needed or using hoses other than
those supplied by manufacturer, flexible hoses with screen filters
are required.
Lower pressures will increase fill times.
Suitable air cushions [risers] should be installed in supply lines to
prevent “hammering.” Refer to Figure 18 .
Connect machine to a backflow preventer (vacuum breaker) be-
fore connecting to the public water main in all countries where
local regulations require specific water approval certificates.
Specifications and Dimensions
F8410701ENR10
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 37