Specifications

Refer to Table 15 .
PHM898N_SVG1
1
A
1. Overflow Vent
Figure 17
Vent Extension (maximum), in. [mm]
Height 45-65 85-150 130-160
A 4 [102] 3.5 [89] 8.25 [210]
Table 15
3. Secure the drain pipe with the hose clamp.
IMPORTANT: Do not route the machine overflow to a
direct drain system.
Drain Information
Specifications 45 65 85 105 130 160
Drain connection size,
O.D., in. [mm] with sec-
ond drain:
3 [76] 3 [76] 3 [76] 3 [76] 3 [76] 3 [76]
Number of drain outlets 1 1 2 (UniLinc)
1 (M30)
2 (UniLinc)
1 (M30)
2 (UniLinc)
1 (M30)
2
Drain flow capacity, gal/
min. [l/min.]
55 [208] 55 [208] 120 [454] 120 [454] 140 [530] 140 [530]
Recommended drain pit
size, ft
3
[l] †
5 [142] 6 [170] 8 [227] 10 [283] 12 [340] 14.5 [411]
†Sized for one machine using overflow level.
Table 16
Drain Line Sizing/Minimum Drain I.D., in. [mm]
Model
Number of Machines
1 2 3 4
45-65 3 [76] 4 [102] 6 [152] 6 [152]
85-160 4 [102] 6 [152] 6 [152] 8 [203]
Table 17
Specifications and Dimensions
36
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT F8410701ENR10