Elevated Pad, in. [mm]
Description
L-speed,
45 (M-
speed)
65 (M-
speed)
45-65
(V-
speed)
85-105 130-160
* Refer to Floor Layout.
Table 11
Tie-in to Existing Floor (refer to Table 3)
CHM2390N_SVG
1
2
B
C
D
A
4
5
3
1. Existing Floor
2. 3500 PSI (minimum) Concrete
3. Reinforcing Bar
4. Perimeter Reinforcing Bar
5. Compacted Fill (minimum 6 in. [152 mm])
Figure 12
Tie-in to Existing Floor, in. [mm]
Description
L-speed,
45 (M-
speed)
65 (M-
speed)
45-65
(V-
speed)
85-105 130-160
A Required thickness of existing
floor (minimum)
6 [152] 6 [152] 6 [152] 6 [152] 6 [152]
B Total depth of
foundation (con-
crete plus 6 in.
[152 mm] fill)
(minimum)
Standard* 12 [305] 14 [356] 18 [457] 18 [457] 18 [457]
Narrow* 14 [356] 16 [406] 20 [508] 20 [508] 20 [508](Side-
by-side)
24 [610](Back-
to-back)
Ultra-narrow* 16 [406] 18 [457] 22 [559] 22 [559] 22 [559](Side-
by-side)
26 [660](Back-
to-back)
Specifications and Dimensions
F8410701ENR10
©