Specifications
Elevated Pad (refer to Table 2)
PHM852N_SVG
1
2
3
B
C
E
D
A
4
5
1. Existing Floor
2. 3500 PSI (minimum) Concrete
3. Reinforcing Bar
4. Perimeter Reinforcing Bar
5. Compacted Fill (minimum 6 in. [152 mm])
Figure 11
Elevated Pad, in. [mm]
Description
L-speed,
45 (M-
speed)
65 (M-
speed)
45-65
(V-
speed)
85-105 130-160
A Height of elevated pad above floor
(maximum)
8 [203] 8 [203] 8 [203] 8 [203] 8 [203]
B Distance between
reinforcing bars
(maximum)
Standard* 12 [305] 12 [305] 12 [305] 12 [305] 12 [305]
Narrow* 6 [152] 6 [152] 6 [152] 6 [152] 6 [152]
Ultra-narrow* 6 [152] 6 [152] 6 [152] 6 [152] 6 [152]
C Length of reinforcing bar extend-
ing into existing Floor (minimum)
2.5 [64] 2.5 [64] 2.5 [64] 2.5 [64] 2.5 [64]
D Total depth of
foundation (con-
crete plus 6 in.
[152 mm] fill)
(minimum)
Standard* 12 [305] 14 [356] 18 [457] 18 [457] 18 [457]
Narrow* 14 [356] 16 [406] 20 [508] 20 [508] 20 [508](Side-
by-side)
24 [610](Back-
to-back)
Ultra-narrow* 16 [406] 18 [457] 22 [559] 22 [559] 26 [660](Side-
by-side)
26 [660](Back-
to-back)
E Required thickness of existing
floor (minimum)
6 [152] 6 [152] 6 [152] 6 [152] 6 [152]
Specifications and Dimensions
30
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT F8410701ENR10