Specifications

ing proper reinforcing bar supports to hold bars at the proper
depth in the pad.
10. Allow adhesive around reinforcing bar to cure properly, refer
to adhesive manufacturer for recommended cure times.
11. Completely fill with 3500 psi concrete up to the existing
foundation level plus any added level (maximum of 8 inch
[203 mm]) for the desired elevated pad. The concrete must be
poured so that the entire foundation and pad cures as one
piece.
12. Allow concrete to cure, refer to manufacturer’s recommended
cure times.
13. Using a mounting bolt template or machine base, mark where
the holes should be drilled to mount the machine.
NOTE: As an alternate method, cast in the Grade 5
(minimum SAE rating), .75 inch [19 mm] anchor
bolts as the concrete is poured, refer to Figure 14 .
Ensure that the bolt threads extend a minimum of
2.75 inches [70 mm] above floor level and a mini-
mum of 6 inches [152 mm] of the bolt is embedded
in concrete.
14. Proceed to Machine Mounting and Grouting section.
Specifications and Dimensions
28
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT F8410701ENR10