Specifications

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Installation
13
803148
Grounding Instructions
The washer must be grounded. In the event of
malfunction or breakdown, grounding will reduce the
risk of electric shock by providing a path of least
resistance for electric current.
The washer is equipped with a cord having an
equipment-grounding conductor and a three-prong
grounding plug. The plug must be plugged into an
appropriate outlet that is properly installed and
grounded in accordance with all local codes and
ordinances.
DO NOT modify the plug provided with the washer –
if it will not fit the outlet, have a proper outlet installed
by a qualified electrician.
NOTE: Have a qualified electrician check the
polarity of the wall receptacle. If a voltage reading
is measured other than that in Figure 11, the
qualified electrician should correct the problem.
Step 8: Check Installation
Refer to Installer Checklist on the back cover of this
manual and make sure that washer is installed
correctly.
Run washer through one complete cycle to make sure
it is operating properly.
Vending
Meter Case
The factory mounted coin meter case does not include
the service door lock, coin drawer, coin drawer lock or
keys. These parts must be ordered (at extra cost)
according to the purchasers requirements direct from
the manufacturer of your choice.
NOTE: You have the option of using a screw type
lock or a 1/4 turn lock on the meter case service
door. If you choose to use a screw lock, then the
special bracket (located inside the meter case) must
be used. DO NOT use the special bracket if a 1/4
turn lock is used.
Coin Drawer Security – For additional security, drill
out the two pilot holes on each side of the front of the
meter case to 1/4 or 5/16 inch (6.4 or 7.9 mm) holes
and install a bicycle lock through these holes.
NOTE: An 8 in. (20.32 cm) coin drawer is required.
Models Prepped for Card Reader
The machine is shipped from the factory with the
Electronic Control Diagnostic Harness Assembly
unplugged. To avoid unauthorized manual
programming or vending, perform the following steps.
1. Open control panel. Refer to Figure 12.
2. Locate diagnostic harness on electronic control.
3. Plug connectors for “white/black” wire and “red/
blue” wire together.
Figure 12
Improper connection of the equipment-
grounding conductor can result in a risk
of electric shock. Check with a qualified
electrician or service person if you are in
doubt as to whether the washer is
properly grounded.
W327
WARNING
FLW6R
1 Control Panel
1