User Manual and Operating Guide
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Installation
802702
18
4. Use the three screws from the accessories bag to 
attach the power cord wires to the terminal block. 
Refer to Figure 13.
Figure 13 
5. Tighten all screws firmly.
IMPORTANT: Failure to tighten these screws 
firmly may result in wire failure at the terminal 
block.
6. Secure the strain relief to the power cord, or 
wires, where they enter the dryer cabinet.
7. Check the continuity of the ground connection 
before plugging the cord into an outlet. Use an 
acceptable indicating device connected to the 
center grounding pin of the plug and the green 
screw on the back of the cabinet.
8. Reinstall access cover and screw.
Connecting Power Cord with Four-Wire Plug
NOTE: Four-wire cord is required for new branch-
circuit installations, mobile homes or where codes 
do not permit grounding through neutral.
Figure 14 
1. Disconnect power to dryer.
2. Remove access cover from rear of dryer.
Figure 15 
D286I
1 “L1” Terminal
2 Neutral Terminal
3 “L2” Terminal
1
2
3
DRY2016N
1 Typical Four-Wire Receptacle
2 Power Cord – Not Supplied with Dryer
3 Strain Relief Nut
4 Strain Relief
D695I
120 ± 12
V.A.C.
120 ± 12
V.A.C.
120 ± 12
V.A.C.
120 ± 12
V.A.C.
240 ± 12
V.A.C.
0
V.A.C.
1
2
3
4