Specifications

Installation
23
801509
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Figure 23
Grounding Instructions
The unit must be grounded. In the event of
malfunction or breakdown, grounding will
reduce the risk of electric shock by providing a
path of least resistance for electric current. The
unit is equipped with a cord having an
equipment-grounding conductor and a three
prong grounding plug. The plug must be plugged
into an appropriate outlet that is properly
installed and grounded in accordance with all
local codes and ordinances.
DO NOT modify the plug provided with the
dryer unit – if it will not fit the outlet, have a
proper outlet installed by a qualified electrician.
If the laundry room’s electrical supply does not
meet the above specifications and/or if you are
not sure the laundry room has an effective
ground, have a qualified electrician or your local
electrical utility company check it and correct
any problems.
D438I
1 L1
2 Ground
3 Neutral
4 Round Grounding Prong
5 Neutral Side
D438i
1
3
4
2
115 ± 12
V.A.C.
0
V.A.C.
115 ± 12
V.A.C.
STANDARD 120 VOLT, 60 HERTZ, 3-WIRE
EFFECTIVELY GROUNDED CIRCUIT
5
Improper connection of the equipment-
grounding conductor can result in a risk of
electric shock. Check with a qualified
electrician or service person if you are in
doubt as to whether the unit is properly
grounded.