Instruction manual
63
501506
Each time the coin vault is opened, the count on the
VFD display increases. This routine tests if the coin
vault counter is operating properly. During this test,
the coin vault counter will save the time and date of
the initial opening of the test. All further test openings
have no effect on the coin vault opening counter.
To exit the Coin Vault Opening Test, press the HIGH
TEMP pad or open the dryer door. When the test is
complete, the control will revert back to the “Ready”
mode.
Service Door Opening Test
To start this test, follow steps 1–4 in
“How to Enter
Testing Feature.”
Next, press the MED TEMP pad.
The VFD display will show “S:OO,”
Figure 99
.
DRYING
DOOR OPEN
COOL DOWN
PRICE
TIME REMAINING
INSERT COINS
PUSH START
C178IE1A
Figure 99
Each time the service door is opened, the count on
the VFD increases. This routine tests if the service
door counter is operating properly. During this test,
the service door counter will save only the time/date
of the initial opening of the test. All further test
openings have no effect on the service door opening
counter.
To exit the Service Door Opening Test, press the
MED TEMP pad or open the dryer door. When the
test is complete, the control will revert back to the
“Ready” mode.
Coin Drop Input Test
To start this test, follow steps 1–4 in
“How to Enter
Testing Feature.”
Next, press the LOW TEMP pad.
The VFD display will show “C:OO,”
Figure 100
.
DRYING
DOOR OPEN
COOL DOWN
PRICE
TIME REMAINING
INSERT COINS
PUSH START
C179IE1A
Figure 100
Each time a coin is entered, the count on the VFD
increases. Coins entered during this test will be
added to the total number of test coins and not the
total number of coins. This routine tests if the coin
drop counter is operating properly. To exit this test,
press the LOW TEMP pad or open the dryer door.
When the test is complete, the control will revert back
to the “Ready” mode.