Instruction manual
56
501506
27. Set Real-Time Clock (date)
“CdE”
This option allows the user to set the Electronic
Control's internal clock to the correct day of the
month.
How to Program Set Real-Time Clock
(date) “CdE”
1. Control must be in Special Mode. Refer to
Section VII.
2. While pressing and holding the HIGH TEMP
pad with one hand, press the MED TEMP pad
with the other hand. Programmable option
number 1 (Audio Signal “SIg”) will appear in
the VFD,
Figure 87
.
DRYING
DOOR OPEN
COOL DOWN
PRICE
TIME REMAINING
INSERT COINS
PUSH START
C146IE1A
Figure 87
3. Press the LOW TEMP (+) pad or the NO
HEAT (–) pad to scroll through the
programmable options until “CdE” appears in
the VFD,
Figure 88
.
DRYING
DOOR OPEN
COOL DOWN
PRICE
TIME REMAINING
INSERT COINS
PUSH START
C173IE1A
Figure 88
4. When “CdE” appears in the VFD, press the
START pad. The current day of the month will
be displayed.
5. Press the LOW TEMP (+) pad or the NO
HEAT (–) pad to increase or decrease the day
of the month until correct,
Figure 89
.
NORMAL
HIGH
TEMP
PERM
PRESS
MED TEMP
DELICATES
LOW
TEMP
TUMBLE
NO
HEAT
START
Press this pad to
scroll ahead or
increase (+) values
Press this pad to
scroll back or
decrease (-) values
Press this pad to
choose (enter) selected
options or values
C147IE1A
Figure 89
6. When the correct day of the month appears in
the VFD, press the START pad to enter the
corrected day. The next programmable option,
“COn,” will appear in the VFD.
NOTE: To program “COn” (Set Real-Time Clock
Month), see the following page. To program other
options, refer to the appropriate section.
How to Exit Programming Feature
1. Be sure service door has been opened and
closed. Refer to Section VI.
2. While pressing and holding the HIGH TEMP
pad with one hand, press the MED TEMP pad
with the other hand. The control will revert
back to the “Ready” mode. See
Figure 3
.