Instruction manual

52
501506
Daylight Savings This option automatically sets the clock in the Electronic Control to account for the time
change during Daylight Savings.
OFF = Turns off the automatic daylight savings option programmed in the Electronic Control.
ON = Turns on the automatic daylight savings option programmed in the Electronic Control.
Fahrenheit/Celsius This option determines if temperatures will be displayed in Celsius or Fahrenheit
F = Temperature readings will be displayed in Fahrenheit.
C = Temperature readings will be displayed in Celsius.
Infra-red Access This option determines if a Micro-Wand can access or program the Electronic Control.
OFF = Turns off the infra-red access by the Micro-Wand.
ON = Turns on the infra-red access by the Micro-Wand.
Decimal Point This option determines if a decimal point is used when displaying the vend price.
For example: Machines using token currency may choose to remove the decimal
point.
OFF = Turns off the decimal point from appearing in the VFD.
ON = Turns on the decimal point to appear in the VFD.
Automatic Collect This option will determine if audit information may be automatically collected by a
Micro-Wand. When programming the cycle parameters in the dryer control with the
Micro-Wand, the Micro-Wand will automatically collect the audit information if Automatic
Collect is turned ON. This is done so the audit information will remain accurate even
with vend price changes. If Automatic Collect is turned OFF, the Micro-Wand user will
not access private audit information when programming the dryer.
OFF = Turns off the ability of the Micro-Wand to collect audit information when programming the machine.
ON = Allows the Micro-Wand to automatically collect audit information when programming the machine.
How to Read
Chart 9
The configuration option (
Chart 9
) is used to enable/
disable the preprogrammed daylight savings option,
Fahrenheit/Celsius option, infrared access option,
decimal option, and the automatic collect option in the
Electronic Control. To change any or all of these
configuration options, review the following
descriptions carefully and choose the appropriate
configuration value in
Chart 9
. Next, enter the
appropriate value in step 6 on the previous page.
Configuratio
Value
Daylight
Savings
Fahrenhei
Celsius
Infra-red
Access
Decim
Point
Automatic
Collect
000 OFF F OFF OFF ON
001 OFF F OFF OFF OFF
008 OFF F OFF ON ON
009 OFF F OFF ON OFF
016 OFF F ON OFF ON
017 OFF F ON OFF OFF
024 OFF F ON ON ON
025 OFF F ON ON OFF
064 OFF C OFF OFF ON
065 OFF C OFF OFF OFF
072 OFF C OFF ON ON
073 OFF C OFF ON OFF
080 OFF C ON OFF ON
081 OFF C ON OFF OFF
088 OFF C ON ON ON
089 OFF C ON ON OFF
Configuratio
Value
Daylight
Savings
Fahrenhei
Celsius
Infra-red
Access
Decim
Point
Automatic
Collect
128 ON F OFF OFF ON
129 ON F OFF OFF OFF
136 ON F OFF ON ON
137 ON F OFF ON OFF
144 ON F ON OFF ON
145 ON F ON OFF OFF
152 ON F ON ON ON
153 ON F ON ON OFF
192 ON C OFF OFF ON
193 ON C OFF OFF OFF
200 ON C OFF ON ON
201 ON C OFF ON OFF
208 ON C ON OFF ON
209 ON C ON OFF OFF
216 ON C ON ON ON
217 ON C ON ON OFF
CHART 9
Configuration Value Chart CFg