Instruction manual
49
501506
22. Power Fail Reset “rPF”
This option allows the user to set the amount of time
the Electronic Control will store active cycle
information in the event of a power failure. The
default settings for Power Fail Reset is five minutes.
How to Program the Power Fail Reset
“rPF”
1. Control must be in Special Mode. Refer to
Section VII.
2. While pressing and holding the HIGH TEMP
pad with one hand, press the MED TEMP pad
with the other hand. Programmable option
number 1 (Audio Signal “SIg”) will appear in
the VFD,
Figure 72
.
DRYING
DOOR OPEN
COOL DOWN
PRICE
TIME REMAINING
INSERT COINS
PUSH START
C146IE1A
Figure 72
3. Press the LOW TEMP (+) pad or the NO
HEAT (–) pad to scroll through the
programmable options until “rPF” appears in
the VFD,
Figure 73.
DRYING
DOOR OPEN
COOL DOWN
PRICE
TIME REMAINING
INSERT COINS
PUSH START
C168IE1A
Figure 73
4. When “rPF” appears in the VFD, press the
START pad. A three-digit number will appear
in the VFD.
NOTE: The number appearing in the VFD is the
current number that was previously selected from
Chart 8
on the next page. The default setting 005
will show in the VFD, which is equal to five
minutes with Power Fail Reset OFF.
5. Locate the desired three-digit number in the
first column of
Chart 8
.
6. Press the LOW TEMP (+) pad or the NO
HEAT (–) pad to increase or decrease the
current three-digit number to the desired three-
digit number selected from
Chart 8
,
Figure 74
.
NORMAL
HIGH
TEMP
PERM
PRESS
MED TEMP
DELICATES
LOW
TEMP
TUMBLE
NO
HEAT
START
Press this pad to
scroll ahead or
increase (+) values
Press this pad to
scroll back or
decrease (-) values
Press this pad to
choose (enter) selected
options or values
C147IE1A
Figure 74
7. Press the START pad when the correct three-
digit number appears in the VFD. The next
programmable option, “CFg,” will appear in the
VFD.
NOTE: To program “CFg” (Control Configuration),
see option 23. To program other options, refer to
the appropriate section.
How to Exit Programming Feature
1. Be sure service door has been opened and
closed. Refer to Section VI.
2. While pressing and holding the HIGH TEMP
pad with one hand, press the MED TEMP pad
with the other hand. The control will revert
back to the “Ready” mode. See
Figure 3
.