Instruction manual

48
501506
21. Default Cycle Status dCS
This option allows the user to set the default cycle the
machine will enter when in Ready mode. When
programming the default cycle refer to
Chart 7
on this
page.
How to Program the Default Cycle Status
dCS
1. Control must be in Special Mode. Refer to
Section VII.
2. While pressing and holding the HIGH TEMP
pad with one hand, press the MED TEMP pad
with the other hand. Programmable option
number 1 (Audio Signal SIg) will appear in
the VFD,
Figure 69
.
DRYING
DOOR OPEN
COOL DOWN
PRICE
TIME REMAINING
INSERT COINS
PUSH START
C146IE1A
Figure 69
3. Press the LOW TEMP (+) pad or the NO
HEAT () pad to scroll through the
programmable options until dCS appears in
the VFD,
Figure 70
.
DRYING
DOOR OPEN
COOL DOWN
PRICE
TIME REMAINING
INSERT COINS
PUSH START
C167IE1A
Figure 70
4. When dCS appears in the VFD, press the
START pad. A three-digit number will appear
in the VFD.
NOTE: The number appearing in the VFD is the
current number that was previously selected from
Chart 7
on this page.
5. Locate the desired three-digit number in the
first column of
Chart 7
.
NOTE: To determine the three-digit number to
enter in the following step, refer to
Chart 7
at the
bottom of the page.
6. Press the LOW TEMP (+) pad or the NO
HEAT () pad to increase or decrease the
current three-digit number to the desired three-
digit number selected from
Chart 7
,
Figure 71
.
NORMAL
HIGH
TEMP
PERM
PRESS
MED TEMP
DELICATES
LOW
TEMP
TUMBLE
NO
HEAT
START
Press this pad to
scroll ahead or
increase (+) values
Press this pad to
scroll back or
decrease (-) values
Press this pad to
choose (enter) selected
options or values
C147IE1A
Figure 71
7. Press the START pad when the correct three-
digit number appears in the VFD. The next
programmable option, rPF, will appear in the
VFD.
NOTE: To program rPF (Reset After Power
Failure), see the following page. To program other
options, refer to the appropriate section.
NUMBER TO ENTER IN
STEP 6
DEFAULT CYCLE
001 Tumble - NO HEAT
002 Delicates - LOW TEMP
004
Perm Press - MED
TEMP
008 Normal - HIGH TEMP
CHART 7
How to Exit Programming Feature
1. Be sure service door has been opened and
closed. Refer to Section VI.
2. While pressing and holding the HIGH TEMP
pad with one hand, press the MED TEMP pad
with the other hand. The control will revert
back to the Ready mode. See
Figure 3
.