Instruction manual

43
501506
17. Additional Time Add
This option allows the user to set the amount of time
that is added to a cycle whenever additional coin(s)
are entered after the vend price has been satisfied.
How to Program Additional Time Add
1. Control must be in Special Mode. Refer to
Section VII.
2. While pressing and holding the HIGH TEMP
pad with one hand, press the MED TEMP pad
with the other hand. Programmable option
number 1 (Audio Signal SIg) will appear in
the VFD,
Figure 57
.
DRYING
DOOR OPEN
COOL DOWN
PRICE
TIME REMAINING
INSERT COINS
PUSH START
C146IE1A
Figure 57
3. Press the LOW TEMP (+) pad or the NO
HEAT () pad to scroll through the
programmable options until Add appears in
the VFD,
Figure 58
.
DRYING
DOOR OPEN
COOL DOWN
PRICE
TIME REMAINING
INSERT COINS
PUSH START
C163IE1A
Figure 58
4. When Add appears in the VFD, press the
START pad. A three-digit number will appear
in the VFD.
NOTE: The number appearing in the VFD is the
current number that was previously selected from
Chart 6
on the following page.
5. Locate the desired three-digit number in the
first column of
Chart 6
on the following page.
NOTE: To determine the three-digit number to
enter in the following step, refer to How to Use
This Chart for
Chart 6
on the following page.
6. Press the LOW TEMP (+) pad or the NO
HEAT () pad to increase or decrease the
current three-digit number to the desired three-
digit number from
Chart 6
,
Figure 59
.
NORMAL
HIGH
TEMP
PERM
PRESS
MED TEMP
DELICATES
LOW
TEMP
TUMBLE
NO
HEAT
START
Press this pad to
scroll ahead or
increase (+) values
Press this pad to
scroll back or
decrease (-) values
Press this pad to
choose (enter) selected
options or values
C147IE1A
Figure 59
7. Press the START pad when the correct three-
digit number appears in the VFD. The next
programmable option, FPr, will appear in the
VFD.
NOTE: To program FPr (NO HEAT Vend Price),
see option 18. To program other options, refer to
the appropriate section.
How to Exit Programming Feature
1. Be sure service door has been opened and
closed. Refer to Section VI.
2. While pressing and holding the HIGH TEMP
pad with one hand, press the MED TEMP pad
with the other hand. The control will revert
back to the Ready mode. See
Figure 3
.