13. MED TEMP Cool Down Time
“PCL”
This option allows the user to set the amount of cool
down time allowed in the MED TEMP cycle. It is
recommended to set the cool down time for more than
three minutes.
How to Program MED TEMP Cool Down
Time “PCL”
1. Control must be in Special Mode. Refer to
Section VII.
2. While pressing and holding the HIGH TEMP
pad with one hand, press the MED TEMP pad
with the other hand. Programmable option
number 1 (Audio Signal “SIg”) will appear in
the VFD,
Figure 45.
DRYING
DOOR OPEN
COOL DOWN
PRICE
TIME REMAINING
INSERT COINS
PUSH START
C146IE1A
Figure 45
3. Press the LOW TEMP (+) pad or the NO
HEAT (–) pad to scroll through the
programmable options until “PCL” appears in
the VFD,
Figure 46
.
DRYING
DOOR OPEN
COOL DOWN
PRICE
TIME REMAINING
INSERT COINS
PUSH START
C159IE1A
Figure 46
4. When “PCL” appears in the VFD, press the
START pad. The current number of minutes of
Cool Down will display in the VFD.
5. Press the LOW TEMP (+) pad or the NO
HEAT (–) pad to increase or decrease the
current number of minutes allowed in Cool
Down,
Figure 47
.
NORMAL
HIGH
TEMP
PERM
PRESS
MED TEMP
DELICATES
LOW
TEMP
TUMBLE
NO
HEAT
START
Press this pad to
scroll ahead or
increase (+) values
Press this pad to
scroll back or
decrease (-) values
Press this pad to
choose (enter) selected
options or values
C147IE1A
Figure 47
6. When the correct number of minutes appears
in the VFD, press the START pad to enter the
corrected number. The next programmable
option, “PdE,” will appear in the VFD.
NOTE: To program “PdE” (MED TEMP
Temperature), see the following page. To program
other options, refer to the appropriate section.
How to Exit Programming Feature
1. Be sure service door has been opened and
closed. Refer to Section VI.
2. While pressing and holding the HIGH
TEMP pad with one hand, press the
MED TEMP pad with the other hand. The
control will revert back to the “Ready” mode.
See
Figure 3
.