5. Press the LOW TEMP (+) pad or the NO
HEAT (–) pad to increase or decrease the
number of minutes displayed in the VFD to the
desired number of minutes,
Figure 26
.
NORMAL
HIGH
TEMP
PERM
PRESS
MED TEMP
DELICATES
LOW
TEMP
TUMBLE
NO
HEAT
START
Press this pad to
scroll ahead or
increase (+) values
Press this pad to
scroll back or
decrease (-) values
Press this pad to
choose (enter) selected
options or values
C147IE1A
Figure 26
6. When the correct number of minutes appears
in the VFD, press the START pad to enter the
corrected number. The next programmable
option, “AFL,” will appear in the VFD.
NOTE: To program “AFL” (Special Vend A NO
HEAT Time), see the following page. To program
other options, refer to the appropriate section.
How to Exit Programming Feature
1. Be sure service door has been opened and
closed. Refer to Section VI.
2. While pressing and holding the HIGH TEMP
pad with one hand, press the MED TEMP pad
with the other hand. The control will revert
back to the “Ready” mode. See
Figure 3
.
6. Special Vend A, Normal Time
“AnL”
This option allows the user to set the normal (heated
cycle) time for Special Vend A.
How to Program the Special Vend A
Normal Time “AnL”
1. Control must be in Special Mode. Refer to
Section VII.
2. While pressing and holding the HIGH TEMP
pad with one hand, press the MED TEMP pad
with the other hand. Programmable option
number 1 (Audio Signal “SIg”) will appear in
the VFD,
Figure 24
.
DRYING
DOOR OPEN
COOL DOWN
PRICE
TIME REMAINING
INSERT COINS
PUSH START
C146IE1A
Figure 24
3. Press the LOW TEMP (+) pad or the NO
HEAT (–) pad to scroll through the
programmable options until “AnL” appears in
the VFD,
Figure 25
.
DRYING
DOOR OPEN
COOL DOWN
PRICE
TIME REMAINING
INSERT COINS
PUSH START
C152IE1A
Figure 25
4. When “AnL” appears in the VFD, press the
START pad. The current number of minutes in
a cycle will appear in the VFD.