Instruction manual

31
501506
5. Special Vend A, NO HEAT
Price AFP
This option allows the user to set the NO HEAT cycle
price for Special Vend A.
In this option the user will set the number of coins
needed to satisfy the NO HEAT vend price.
NOTE: This option is directly related to option 20
(Coin Value COI). If the coin value is set for U.S.
currency, and the coin drop accepts only quarters,
the coin value should be set for 025. Therefore,
each time a quarter is entered into the coin drop,
the vend price will decrease 25 cents.
How to Set the Special Vend A NO HEAT
Price
1. Control must be in Special Mode. Refer to
Section VII.
2. While pressing and holding the HIGH TEMP
pad with one hand, press the MED TEMP pad
with the other hand. Programmable option
number 1 (Audio Signal SIg) will appear in
the VFD,
Figure 21
.
DRYING
DOOR OPEN
COOL DOWN
PRICE
TIME REMAINING
INSERT COINS
PUSH START
C146IE1A
Figure 21
3. Press the LOW TEMP (+) pad or the NO
HEAT () pad to scroll through the
programmable options until AFP appears in
the VFD,
Figure 22
.
DRYING
DOOR OPEN
COOL DOWN
PRICE
TIME REMAINING
INSERT COINS
PUSH START
C151IE1A
Figure 22
4. When AFP appears in the VFD, press the
START pad. The current number of coins
required to fulfill the Special Vend A NO HEAT
price will appear in the VFD.
5. Press the LOW TEMP (+) pad or the NO
HEAT () pad to increase or decrease the
current number of coins displayed in the VFD
to the desired number of coins,
Figure 23
.
NORMAL
HIGH
TEMP
PERM
PRESS
MED TEMP
DELICATES
LOW
TEMP
TUMBLE
NO
HEAT
START
Press this pad to
scroll ahead or
increase (+) values
Press this pad to
scroll back or
decrease (-) values
Press this pad to
choose (enter) selected
options or values
C147IE1A
Figure 23
6. When the correct number of coins appears in
the VFD, press the START pad to enter the
correct number. The next programmable
option, AnL, will appear in the VFD.
NOTE: To program AnL (Special Vend A Normal
Time), see the following page. To program other
options, refer to the appropriate section.
How to Exit Programming Feature
1. Be sure service door has been opened and
closed. Refer to Section VI.
2. While pressing and holding the HIGH TEMP
pad with one hand, press the MED TEMP pad
with the other hand. The control will revert
back to the Ready mode. See
Figure 3
.