Instruction manual

21
501506
Section VIII
Programming the Electronic Control
What Can Be Programmed?
This feature allows the owner to program cycle
information, standard vend pricing, special vends, and
others. Refer to this section when programming the
Electronic Control.
This section offers a detailed description of all 29
options available for programming.
Each description includes instructions on when and
why the option might be used and, more importantly,
how to program the option.
For more advanced users, a quick reference list of the
options available through the programming mode is
located on this page.
NOTE: The three letters in the Option column of
the Programmable Options List is what will show
in the VFD display when that option is selected.
* Options marked with an asterisk are for basic
start-up programming.
Programmable Options Available
# OPTION DESCRIPTION
1
"Slg"
Audio Signal
*2 "nPr" Normal Vend Price
3 "SPA" Special Vend A ON/OFF Days of Week
4 "AnP" Special Vend A Normal Price
5 "AFP" Special Vend A NO HEAT Price
6 "AnL" Special Vend A Normal Time
7 "AFL" Special Vend A NO HEAT Time
8 "ASH" Special Vend A Start Hour
9 "AEH" Special Vend A End Hour
*10
"nCL"
Normal Cycle (HIGH, MED, LOW) Time
*11
"HCL"
HIGH TEMP Cool Down Time
*12
"HdE"
HIGH TEMP Temperature
*13
"PCL"
MED TEMP Cool Down Time
*14 "PdE" MED TEMP Temperature
*15 "LCL" LOW TEMP Cool Down Time
*16 "LdE" LOW TEMP Temperature
*17 "Add" Additional Time
*18 "FPr" NO HEAT Vend Price
*19 "FCL" NO HEAT Cycle Time
*20 "COI" Coin Value
21
"dCS"
Default Cycle Status
22
"rPF"
Reset After a Power Failure
23 "CFg"
Control Configuration
- Daylight Savings
- Fahrenheit/Celcius
- Decimal Point
- Infra-red Access
- Auto Collect
24 "Cln" Set Real-Time Clock (minutes)
25 "CHr" Set Real-Time Clock (hours)
26
"CdA"
Set Real-Time Clock (days of week)
27
"CdE"
Set Real-Time Clock (date)
28
"COn"
Set Real-Time Clock (month)
29
"CYr"
Set Real-Time Clock (year)