Specifications

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Installation
F8429301 (EN)
50
40 Pound Capacity Models
Voltage Designation Standard Electric Heat
Code
Voltage
Cycle
Phase
Wire
Full Load
Amps
Circuit
Breaker
AWG
mm
2
Full Load
Amps
Circuit
Breaker
AWG
mm
2
F-Speed Models
X 220 – 240 60 1/3 2/3 6/4 15 14 2.5 N/A
Q 220 – 240 60 3 3 4 15 14 2.5 42 50 8 10.0
N 440 – 480 60 3 3 3 15 14 2.5 22 30 10 6.0
P 380 – 415 50 3 3 3 15 14 2.5 25 30 10 6.0
V-Speed Models
X 220 – 240 60 1/3 2/3 7/4 15 14 2.5 N/A
Q 220 – 240 60 3 3 4 15 14 2.5 42 50 8 10.0
N 440 – 480 60 3 3 3 15 14 2.5 22 30 10 6.0
P 380 – 415 50 3 3 3 15 14 2.5 25 30 10 6.0
NOTE: Wire sizes shown are for copper, THHN, 90°C conductor per NEC article 310.
Table 12
60 Pound Capacity Models
Voltage Designation Standard Electric Heat
Code
Voltage
Cycle
Phase
Wire
Full Load
Amps
Circuit
Breaker
AWG
mm
2
Full Load
Amps
Circuit
Breaker
AWG
mm
2
F-Speed Models
X 220 – 240 60 1/3 2/3 9/6 15 14 2.5 N/A
Q 220 – 240 60 3 3 6 15 14 2.5 43 50 8 10.0
N 440 – 480 60 3 3 4 15 14 2.5 22 30 10 6.0
P 380 – 415 50 3 3 4 15 14 2.5 25 30 10 6.0
V-Speed Models
X 220 – 240 60 1/3 2/3 10/6 15 14 2.5 N/A
Q 220 – 240 60 3 3 6 15 14 2.5 43 50 8 10.0
N 440 – 480 60 3 3 4 15 14 2.5 22 30 10 6.0
P 380 – 415 50 3 3 4 15 14 2.5 25 30 10 6.0
NOTE: Wire sizes shown are for copper, THHN, 90°C conductor per NEC article 310.
Table 13