Three-Phase Connections
For three-phase input, connect L1, L2, L3 and Ground
as shown in Figure 43.
IMPORTANT: If a stinger leg is used for three-
phase input, it MUST be connected to L3.
Grounding
For personal safety and proper operation, the machine
must be grounded in accordance with state and local
codes. If such codes are not available, grounding must
conform to the National Electric Code, article 250
(current edition).The ground connection must be made
to a proven earth ground, not to conduit or water pipes.
Figure 44
Figure 45
Machines can be converted for lower voltage
operation and/or 50 Hz operation. Refer to conversion
label by nameplate for details.
Phase Adder
IMPORTANT: Do not use a phase adder on any
machine.
Thermal Overload Protector
For variable-speed machines, the AC drive provides
overload protection for the drive motor.
CHM2407N
Figure 43
L1
Ground
L2
L3
Electrically heated machines DO NOT
require dual power sources. Do not
connect customer power or customer
load to the Internal Load Distribution
terminal block. Refer to the machine
electrical schematic for details.
W759
WARNING
CHM2380N
1 Grounding Lug: Connect to proven earth
ground
2 Customer Input Power Terminals
3 Internal Load Distribution - DO NOT connect
customer power source or load.
CHM2381
1 Grounding Lug: Connect to proven earth
ground
2 Customer Input Power Terminals
SERVICE
GROUND
CHASIS
TB1
CHM2380N
L1 L2 L3
2
1
3
MACHINES WITH ELECTRIC HEAT
SERVICE
GROUND
CHASIS
TB1
CHM2381N
2
1
MACHINES WITHOUT ELECTRIC HEAT