Specifications
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Installation
F8429301 (EN)
30
Elevated Pad Installation with Existing
Floor
The existing floor slab must meet minimum
requirements shown in Table 2 per machine. The floor
must be reinforced concrete without voids under slab.
If the slab meets these requirements and an elevated
pad is desired, refer to Figures 19, 22, 31, and 34 and
proceed to Machine Foundation and Pad Installation
section.
Elevated Base Frame Installation with
Existing Floor
The existing floor slab must meet minimum
requirements shown in Table 2 per machine. The floor
must be reinforced concrete without voids under slab.
If the slab meets these requirements and an elevated
base frame is desired, refer to Figures 17, 18, 20, 21,
23, 24 and 26 and proceed to Machine Mounting and
Grouting section.
Figure 17
New Foundation
If the existing floor slab does not meet the single
machine foundation requirements per model, refer to
Figures 20, 23, 32, and 35 and proceed to Machine
Foundation and Pad Installation section.
Isolated Pad Installation
This type of installation is NOT recommended.
Installer MUST consult a Structural Engineer for
concrete specifications and requirements for
installations that will not be tied into adjacent
foundations.
IMPORTANT: The above instructions and
recommendations are conservative specifications
for a typical installation based on consultations
with a structural engineer. Alliance Laundry
Systems stands behind all installations meeting
these specifications. For alternate installation
specifications based on your soil type, location,
building structure, unique floor geometry, machine
types, and utilities, consult a structural engineer in
your local area.
H035I
H035I