Specifications
Specifications and Dimensions
11
F8429301 (EN)
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
(continued)
Specification 20 30 40 60 80 100 125
Cylinder Speeds
Gentle wash/reverse speed,
RPM (G)
37 (0.4) 34 (0.4) 33 (0.4) 31 (0.4) 28 (0.4) 28 (0.4) 26 (0.4)
Wash/reverse speed,
RPM (G)
51 (0.8) 48 (0.8) 46 (0.8) 43 (0.8) 39 (0.8) 39 (0.8) 36 (0.8)
Distribution speed,
RPM (G)
92 (2.5) 86 (2.5) 82 (2.5) 77 (2.5) 70 (2.5) 70 (2.5) 64 (2.6)
Extract Speed 1 (very low),
RPM (G)
301 (27) 282 (27) 269 (27) 252 (27) 230 (27) 230 (27) 256 (40)
Extract Speed 2 (low),
RPM (G)
518 (80) 485 (80) 464 (80) 434 (80) 396 (80) 396 (80) 362 (80)
Extract Speed 3 (medium),
RPM (G)
579 (100) 542 (100) 518 (100) 485 (100) 443 (100) 443 (100) 405 (100)
Extract Speed 4 (high),
RPM (G)
648 (120) 606 (120) 579 (120) 542 (120) 495 (120) 495 (125) 444 (120)
Extract Speed 5 (very
high), RPM (G)
710 (150) 664 (150) 635 (150) 594 (150) 542 (150) 542 (150) 479 (140)
Extract Speed 6 (ultra
high), RPM (G)
819 (200) 766 (200) 733 (200) 686 (200) 626 (200) 568 (165) N/A
Direct Steam Heating (Optional)
Steam inlet connection
size, NPT
1/2 1/2 1/2 1/2 1/2 1/2 3/4
Number of steam inlets ** ** 1 1 1 1 1
Steam required to
raise bath water
temperature
10°F (10°C),
lbs. (kg)
LOW
.74
(0.34)
.94
(0.43)
2.09
(0.94)
3.80
(1.63)
3.80
(1.72)
3.80
(1.72)
3.64
(1.65)
MED
1.07
(0.49)
1.28
(0.58)
2.40
(1.09)
4.65
(2.11)
4.65
(2.11)
5.49
(2.49)
5.17
(2.35)
HIGH
1.44
(0.65)
1.74
(0.79)
2.84
(1.29)
5.79
(2.63)
5.79
(2.63)
6.84
(3.10)
7.78
(3.52)
Average steam use per
cycle, bhp
.34 .41 .78 .98 1.34 1.58 1.14
Electrical Heating
Total electrical
heating capacity,
kW
Input
Voltage
200V 5.4 5.4 10.8 10.8 19.1 N/A N/A
240V 7.8 7.8 15.6 15.6 27.4 N/A N/A
380V 6.5 6.5 13.0 13.0 17.2 34.4 34.4
415V 7.8 7.8 15.5 15.5 20.5 41.0 41
480V N/A N/A 15.6 15.6 27.4 54.8 54.8
Electrical heating elements 3 3 6 6 6 12 12
Electrical heat element
size, kW
2.6 2.6 2.6 2.6 4.2 2.6
4.2
Noise Emissions
dBA
Wash 58 58 58 58 58 58 N/A
Extract
100G 52 59 59 59 69 69 N/A
200G 61 66 66 66 76 76 N/A
* For B, Q, and X-voltage models = 1 hp (.75 kW) and for N and P-voltage models = 2 hp (1.7 kW)
** 20 and 30 pound models can be prep for steam and a kit is available for conversion.