Specifications

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
10
F8429301 (EN)
Specifications and Dimensions
Specification 20 30 40 60 80 100 125
Weight and Shipping Information
Net weight,
lbs. (kg)
335
(152)
460
(209)
550
(249)
695
(315)
1210
(549)
1260
(572)
2301
(1044)
Standard shipping weight,
lbs. (kg)
365
(166)
495
(225)
590
(268)
745
(338)
1260
(572)
1310
(594)
2384
(1081)
Standard shipping
volume, ft
3
(m
3
)
26.5
(0.75)
35.8
(1.01)
43.9
(1.24)
57.3
(1.62)
81.3
(2.30)
87.3
(2.5)
163
(4.3)
Standard shipping
dimensions (WxHxD),
in. (mm)
28x33.8x48.4
(711x859x
1229)
31.5x38.3x51.3
(800x973x
1303)
32.5x43.5x53.6
(826x1105x
1361)
37.5x46.9x56.3
(953x1191x
1430)
44x54.5x58.6
(1118x1384x
1488)
44x58.5x58.6
(1118x1486x
1488)
56x61.5x77.8
(1422x1562x
1976)
Slat crate shipping
weight, lbs. (kg)
450
(204)
590
(268)
690
(313)
860
(390)
1385
(628)
1435
(651)
2492
(1130)
Slat crate shipping
volume, ft
3
(m
3
)
36.2
(1.04)
47.3
(1.34)
54.1
(1.53)
77.6
(2.20)
105
(2.97)
112.4
(3.18)
173
(4.8)
Slat crate shipping
dimensions (WxHxD),
in. (mm)
32.5x36.8x49.8
(826x935x
1240)
36x41.3x55
(914x1049x
1397)
37x45.9x55
(940x1166x
1397)
42x49.9x64
(1067x1267x
1626)
48.5x57.5x65.1
(1232x1461x
1654)
48.5x61.5x65.1
(1232x1562x
1654)
59x64.5x80
(1499x1638x
2032)
Wash Cylinder Information
Cylinder diameter,
in. (mm)
21
(533)
24
(610)
26.25
(667)
30
(762)
36
(914)
36
(914)
43
(1092)
Cylinder depth,
in. (mm)
13.75
(349)
16
(406)
20.25
(514)
22
(559)
22
(559)
26
(660)
24
(610)
Cylinder volume,
ft
3
(l)
2.76
(78.1)
4.19
(118)
6.34
(180)
9.00
(255)
12.95
(367)
15.32
(434)
19.2
(544)
Perforation size,
in. (mm)
0.188
(4.78)
0.188
(4.78)
0.188
(4.78)
0.188
(4.78)
0.188
(4.78)
0.188
(4.78)
0.188
(4.78)
Perforation open area, % 17.3 18.6 18.8 18.8 19.6 20.2 24
Door Opening Information
Door opening size,
in. (mm)
11.63
(295)
14.34
(364)
16.25
(413)
16.25
(413)
18.5
(470)
18.5
(470)
20
(508)
Height of door bottom
above floor, in. (mm)
14.38
(365)
14
(356)
14.56
(370)
14.94
(379)
17.91
(455)
17.91
(455)
29
(737)
Height of door opening
above floor, in. (mm)
17
(432)
17
(431)
17.74
(451)
18.12
(460)
20.77
(528)
20.77
(528)
30.25
(768)
Power Consumption
Average power
used per cycle,
kW-hr.
(x-voltage
shown)
No
load
.05 .09 .10 .15 .19 .19 .63
80 %
load
.06 .11 .14 .22 .28 .28 .64
Estimated Building Heat Load
HVAC load, Btu/hr.
(Kcal/hr.)
(Non-heat models)
400
(101)
450
(113)
510
(129)
750
(189)
950
(239)
950
(239)
1200
(302)
Drive Train Information
Number of motors in
drive train
1111111
Drive motor power,
hp (kW)
* 2 (1.5) 2 (1.5) 3 (2.2) 5 (3.7) 5 (3.7) 7.5 (5.6)
(continued)