Service manual

800793 53
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the washer before servicing.
Never start the washer with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer is properly grounded.
W003
WARNING
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
g. Gently pull door lock out through door opening.
Remove door lock only far enough to
disconnect harness connector from door lock.
Refer to Figure 16.
NOTE: When installing new door lock, be sure to
install small lip through mounting hole first and
then rotate lock into position.
35. THERMOSTAT (Models equipped with
heater)
a. While supporting lower access panel, remove
two screws from bottom edge of panel and
remove panel. Refer to Figure 9.
b. Remove wire connector from thermostat.
c. Reach up behind front panel, grasp thermostat,
and using a twisting motion, pull thermostat
and rubber grommet out of mounting hole in
outer tub front panel. Refer to Figure 19.
NOTE: The thinner portion of grommet is inserted
into outer tub front panel.
NOTE: The thermostat is installed into grommet
with No. 27615P Sealant (3M800). (Obtain from
local parts distributor).
Figure 19
FLW1644S
THERMOSTAT
GROMMET
HEATING
ELEMENT
ASSEMBLY
NUT AND
LOCKWASHER