Service manual

52 53273
Section 6 Gas Burner Conversion Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
66. CONVERSION KITS For Dual Input Gas
Dryers Equipped with No. 56279 Gas Valve
All dual input gas dryers manufactured with glow
bar ignition are factory equipped for
Natural/Mixed gas operation.
No. 56975 Natural/Mixed to L.P. Gas Kit is
available from your parts supplier. This kit
consists of:
No. 56976 L.P. to Natural/Mixed Gas Kit is
available for field conversion. This kit consists of:
67. ORIFICE INFORMATION
1 - 53390 Block-Open Plug and Gasket
1 - 55753 Valve Converted Sticker
1 - 56426 L.P. Gas Sticker
1 - 56977 Burner Orifice - Inner
1 - 56978 Burner Orifice - Outer
1 - 56979 Change-Over Sticker
1 - 53952 Vent Screw
1 - 55493 Burner Orifice - Outer
1 - 54944 Burner Orifice - Inner
1 - 56427 Natural Gas Sticker
1 - 56980 Change-Over Sticker
1 - 56981 Valve Number Sticker
Burner Orifice
Kind of Gas
Outer
Orifice
Part No.
Inner
Orifice
Part No.
Stamp
Code
Natural/Mixed
55493 - 37T
- 55494 40
Liquefied
Petroleum (L.P.)
56978 - 53T
- 56977 53
Figure 45
DRY1222S
55