Service manual
18 53273
Section 4 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
b. Nonmetered models with timer mounted on
cabinet top.
(1) Refer to Figure 5 for timer removal.
(2) Remove front panel. Refer to Paragraph
13, steps a, b, and c.
(3) Loosen setscrew and pull timer knob off
shaft.
(4) Remove two cabinet top hold-down
screws, Figure 6.
(5) Lift cabinet top on rear hinges and support
it against wall behind dryer.
(6) While holding timer, remove three Phillips
head screws holding timer and spacer to
cabinet top and pull timer away from top to
disconnect wires.
NOTE: Lockwasher must be between head of screw
and cabinet top. Also, spacer must be in place when
reinstalling timer.
NOTE: Refer to appropriate wiring diagram when
rewiring timer.
(7) Remove three screws and lockwasher
holding timer plate and gasket to cabinet
top.
NOTE: When reinstalling, lockwasher must be
between head of screw and timer plate.
Figure 5
DRY1210S
Phillips Head
Screw
Setscrew
Timer
Knob
Lockwasher
Phillips Head
Screw
Timer
Plate
Gasket
Fiber
Washer
Nut
Timer
Spacer
Nut
Lockwasher
Figure 6
DRY856S
Cabinet Top
Hold-Down
Screw