To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
6. IGNITER DOES NOT GLOW (Gas Supply Sufficient) – GAS MODELS
7. BURNER IGNITES AND GOES OUT REPEATEDLY – GAS MODELS
8. IGNITER GLOWS BUT BURNER DOES NOT IGNITE – GAS MODELS
POSSIBLE CAUSE TO CORRECT
No power to power leads on valve. • Check for electrical circuit. Refer to “To Test Electrical
Circuit to Ignition System” on page 27.
Sensor failed with contacts open. • Replace sensor.
Igniter broken or open. • Replace igniter.
Gas Valve - Open booster or holding coils. • Replace gas valve (in-warranty).
• Replace coils (out-of-warranty).
POSSIBLE CAUSE TO CORRECT
Burner heat not holding sensor contacts open. • Replace sensor.
Insufficient gas supply. • Check gas supply and pressure.
POSSIBLE CAUSE TO CORRECT
Sensor failed in closed position. • Replace sensor.
Open secondary coil or holding coil. • Replace gas valve (in-warranty)
• Replace coils (out-of-warranty).
No or insufficient gas supply. • Check gas supply and pressure.