Service manual

53273 11
Section 3 Troubleshooting
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
5. HEATING ELEMENT DOES NOT HEAT OR BURNER DOES NOT IGNITE
POSSIBLE CAUSE TO CORRECT
Improper or inadequate exhaust system. See Installation Instructions (supplied with dryer) for
exhaust requirements.
Blown house fuse or tripped circuit breaker. Check fuses or circuit breakers.
FABRIC switch set at FLUFF, or inoperative. Reset or test switch and replace if inoperative.
Timer improperly set - nonmetered models. Reset timer.
Inoperative limit thermostat. Test thermostat and replace if inoperative.
Electric Models: Inoperative heating element. Replace element.
Gas Models: Insufficient gas supply. Open partially closed gas shut-off valve, or correct low
gas pressure.
Inoperative drive motor switch. Test switch and replace if inoperative.
Gas Models: Inoperative gas valve coils. Test coils and replace if inoperative.
Gas Models: Inoperative igniter. Test igniter and replace if inoperative.
Gas Models: Inoperative sensor. Test sensor and replace if inoperative.
Inoperative high, low or limit thermostat. Test thermostat and replace if inoperative.
Inoperative timer - nonmetered models. Test timer and replace if inoperative.
Inoperative accumulator - metered models. Test accumulator and replace if inoperative.
Broken, loose, or incorrect wiring. Refer to appropriate wiring diagram.