Service manual

84 800170
Section 3 Troubleshooting (Dryer)
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the washer/dryer before servicing.
Close gas shut-off valve to gas dryer before servicing.
Never start the washer/dryer with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer/dryer is properly grounded.
W014R1
WARNING
40. HEATING ASSEMBLY DOES NOT HEAT OR BURNER DOES NOT IGNITE
41. IGNITER DOES NOT GLOW (Gas Supply Sufficient) – GAS MODELS
POSSIBLE CAUSE TO CORRECT
Improper or inadequate exhaust system. Refer to Installation Instructions (supplied with dryer)
for exhaust requirements.
Use of plastic or thin foil exhaust duct. Replace with rigid or semi-rigid metal exhaust duct.
Blown house fuse or tripped circuit breaker. Check fuses or circuit breakers. A 240 Volt dryer uses two
fuses. Make sure both fuses are good.
Temperature selector switch set at FLUFF, or
inoperative.
Reset or test switch and replace if inoperative.
Inoperative limit thermostat. Test thermostat and replace if inoperative.
Inoperative drive motor switch. Test switch and replace if inoperative.
Electric Models: Inoperative heater assembly. Test heater assembly and replace if cold Ohms do not read
between 9 and 10.5 Ohms.
Electric Models: Inoperative thermal fuse. Test thermal fuse and replace if inoperative.
Gas Models: Insufficient gas supply. Check gas shut-off valve in dryer and main gas line valve.
Open partially closed gas shut-off valve, or correct low
gas pressure.
Gas Models: Inoperative gas valve coils. Test coils and replace if inoperative. Refer to Paragraph
142.
Gas Models: Inoperative sensor. Test sensor and replace if inoperative. Refer to Paragraph
117, step c.
Gas Models: Inoperative igniter. Test igniter and replace if inoperative. Refer to Paragraph
144.
Gas Models: Harness not properly connected to gas
controls.
Check harness connections to gas valve coils, sensor and
main harness.
Reconnect as required.
Gas Models: Restricted gas flow in gas orifice. Clean out gas orifice.
Inoperative cycling thermostat. Test thermostat and replace if inoperative.
Broken, loose, or incorrect wiring. Refer to wiring diagram.
POSSIBLE CAUSE TO CORRECT
No power to power leads on valve. Check timer, selector switch, thermostats, motor switch,
and wiring.
Sensor failed with contacts open. Replace sensor.
Igniter broken or open. Replace igniter.