Service manual
800170 219
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer/dryer before servicing.
• Close gas shut-off valve to gas dryer before servicing.
• Never start the washer/dryer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer/dryer is properly grounded.
W014R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Section 7
Dryer Test Procedures
IMPORTANT: Electrical test procedures in this
service manual are performed by using a Volt-Ohm
meter. Tests can also be performed using a multi-
meter or any other electrical testing equipment with
which the service person is familiar.
138. DRIVE MOTOR
Refer to Figure 81.
a. Remove motor and exhaust assembly. Refer to
Paragraph 123.
b. Disconnect motor wire harness at motor
disconnect block.
NOTE: Refer to wiring schematic, Section 8, for
internal motor switch wires.
NOTE: Drive Motor Resistance
120 Volt 2,460 – 3,100 Ohms
240 Volt 10,000 - 13,000 Ohms
Figure 81
2
643 5
1
G
Drive
Motor
Motor and
Exhaust
Assembly
D326SE3A
1
2
4
6
5
3
Motor
Disconnect
Block
Motor
Switch