Service manual
208 800170
Section 5 Service Procedures
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer/dryer before servicing.
• Close gas shut-off valve to gas dryer before servicing.
• Never start the washer/dryer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer/dryer is properly grounded.
W014R1
WARNING
j. Electric Models:
(1) Remove two screws holding element and
plate to heater box, then pull element down
and away from heater box. Refer to
Figure 52.
(2) Remove all wires from terminal block.
(Refer to appropriate wiring diagram when
rewiring terminal block.)
(3) Remove screw holding terminal block to
rear bulkhead. Refer to Figure 69.
k. While supporting bulkhead, remove the four
screws holding rear bulkhead to dryer cabinet,
then lift complete assembly out of dryer. Refer
to Figure 66.
l. Remove heater box from rear bulkhead. Refer
to Figure 68.
Figure 68
Heater
Box
Attaching
Screws
Heater
Box
Attaching
Screws
Heater
Box
Rear
Bulkhead
D261SE3A