Service manual
800170 195
Section 5 Service Procedures
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer/dryer before servicing.
• Close gas shut-off valve to gas dryer before servicing.
• Never start the washer/dryer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer/dryer is properly grounded.
W014R1
WARNING
120. HEATER ASSEMBLY (Electric Models)
a. While supporting access panel, remove two
screws from bottom edge of access panel. Refer
to Figure 40.
b. Gently lower access panel to disengage locators
from bottom edge of front panel. Refer to
Figure 48.
c. Remove two screws holding heater assembly to
heater box and remove heater assembly out
through front of dryer. Refer to Figure 52.
d. Disconnect wires from heater assembly. Refer
to Figure 52.
NOTE: When reassembling, be sure all wire
connectors are tight on element terminals, thermal
fuse and limit thermostat.
121. THERMISTOR
a. While supporting the access panel, remove two
screws from bottom edge of access panel. Refer
to Figure 40.
b. Gently lower the access panel to disengage
locators from bottom edge of front panel. Refer
to Figure 48.
c. Disconnect wires and remove thermistor
attaching screws. Refer to Figure 53.
122. AIR DUCT
a. While supporting the access panel, remove two
screws from bottom edge of access panel. Refer
to Figure 40.
b. Gently lower the access panel to disengage
locators from bottom edge of front panel. Refer
to Figure 48.
Figure 53
Attaching
Screws
Seal
Thermistor
Wire
Harness
D324SE3C
Figure 54
D307SE1D
Front
Bulkhead
Front
Air Duct
Lint
Filter
Screw