Service manual

178 800170
Section 5 Service Procedures
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the washer/dryer before servicing.
Close gas shut-off valve to gas dryer before servicing.
Never start the washer/dryer with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer/dryer is properly grounded.
W014R1
WARNING
Installing 800749P Trunnion Kit or 800198P
Inner Basket Kit –
a. Remove nuts, washers and tension rods holding
trunnion to inner basket. Refer to Figure 35.
b. If using existing trunnion, clean out old Loctite
from pulley bolt threads using a 3/8-24 UNF
Left Hand Tap.
c. Dip threads of three new tension rods into
lightweight oil.
d. Insert tension rods into inner basket. Refer to
Figure 35. Position each rod so the rounded
corner of triangular head faces the center of
inner basket. Refer to Figure 36.
e. Position trunnion assembly through rods and
onto inner basket.
f. Attach three washers and three new nylon
locknuts onto rods. Leave the nuts loose.
IMPORTANT: Always use new nylon locknuts.
g. Carefully center trunnion on basket and torque
nuts to about 50 inch-pounds.
h. Install inner basket/trunnion assembly into
washer. Do not bolt down at this time.
Figure 35
FLW10K
Tension Rod
Inner
Basket
Trunnion
Assembly
Nylon
Locknut
Washer
Figure 36
FLW11K
Tension
Rod Head
Inner
Basket
Rounded
Corner