Service manual
164 800170
Section 5 Service Procedures
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer/dryer before servicing.
• Close gas shut-off valve to gas dryer before servicing.
• Never start the washer/dryer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer/dryer is properly grounded.
W014R1
WARNING
95. MIXING VALVE
NOTE: Mixing valve is located on upper back right
corner of rear panel. Refer to Figure 26.
a. Go to rear of washer and remove screw holding
mixing valve and plate to rear panel, then
remove valve and plate out through opening in
rear panel. Refer to Figure 26.
b. Shut off external hot and cold water supply and
remove two inlet hoses.
c. Remove screws holding valve to mixing valve
plate. Refer to Figure 26.
d. Loosen hose clamp and remove mixing valve-
to-dispenser hose at the mixing valve. Refer to
Figure 26.
e. Remove wire harness disconnect blocks from
mixing valve solenoid terminals. Refer to
Figure 26.
NOTE: Refer to wiring diagram when rewiring
solenoids.