Service manual
800170 13
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer/dryer before servicing.
• Close gas shut-off valve to gas dryer before servicing.
• Never start the washer/dryer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer/dryer is properly grounded.
W014R1
WARNING
Section 3
Troubleshooting
1. TROUBLESHOOTING COIN DROP
When coin is placed into coin slot, the coin should roll
down drop and be heard dropping into coin vault. If
coin does not fall into coin vault or if coin drop sensor
does not register that coin has been entered, follow
troubleshooting instructions on following page. Refer
to Figure 1 for path that coin follows when working
properly.
IMPORTANT: Never use oil to correct coin drop
problems. Oil residue will prevent coins from
rolling properly.
IMPORTANT: Do not bend or damage mechanical
parts within coin drop.
Figure 1
DRY2B
Additional coins
following path to
sensor
Coin Drop
Sensor
Coin in
Coin Slot