Service manual
112 800170
Section 3 Troubleshooting (MDC Models – Dryer Control)
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
62. NO VISIBLE DISPLAY ON CONTROL – DRYER
Replace the 
control.
Correct wiring 
between the 
transformer and 
the control.
Replace the 
transformer.
Are 
there 24 volts AC 
across terminals H1-3 
and H1-1 on the 
control?
Correct wiring to the 
primary of the 
transformer. Make 
sure the machine is 
plugged in and 
power is on.
Are 
there 24 Volts AC 
across the secondary 
of the transformer?
Are 
there 120 volts AC 
to the primary of 
the transformer?
(1)
(2)
(3)
NO
YES
YES
YES
NO
NO
NOTE: Refer to wiring 
diagram for primary 
voltage.
No Display
Dwg. 1
SWD1685S