Instruction manual

Programming NetMaster
511210
94
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Configuration #3 Programming
Use the table below (Ta ble 7) to turn on or turn off access
for Manual Rapid Advance and to change Available
Output Mode.
NOTE: Selecting “Ready Mode” for the available
output will turn off the available output after the
first pulse is received. Selecting “Start Mode” will
keep the available output on until the vend price is
satisfied. This feature is used for aftermarket card
reader or central pay systems.
Manual Rapid
Advance
This option turns on or off the Manual Rapid Advance feature.
OFF = Turns off Manual Rapid Advance.
ON = Turns on Manual Rapid Advance.
“+057”
Config #3 Value Manual Rapid Advance Available Until
0
OFF READY MODE
1 OFF START MODE
2 ON READY MODE
3 ON START MODE
Tab le 7