Instruction manual

Programming NetMaster
59
511210
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
29. Power Fail Reset “+029”
This option allows the owner to set the amount of time
NetMaster will store active cycle information in the
event of a power failure. The default setting for Power
Fail Reset is OFF. If Power Fail Reset is turned OFF,
the cycle will be saved for up to six years.
How to Program Power Fail Reset
1. Control must be in Manual Mode. Refer to
Entering the Manual Mode.
2. Press the LOW TEMP (+) or the NO HEAT (-)
keypad until “PrOg” appears in the VFD. Press
the START (enter) keypad and “+001” will
appear in the VFD.
Figure 114
3. Press the LOW TEMP (+) or the NO HEAT (-)
keypad to scroll through the programmable
options until “+029” appears in the VFD. Refer
to Figure 115.
Figure 115
4. When “+029” appears in the VFD, press the
START (enter) keypad. A number will appear in
the VFD. This number corresponds to the current
Power Fail Reset setting.
5. Press the LOW TEMP (+) or the NO HEAT (-)
keypad to increase or decrease the current
number to the desired number selected from
Table 3. Refer to Figure 116.
Figure 116
6. Press the START (enter) keypad when the correct
number appears in the VFD. The next option,
+030”, will appear in the VFD.
NOTE: To program “+030” (Default Cycle), refer
to option 30. To program other options, refer to the
appropriate section.
How to Exit Programming Feature
1. Be sure the control shows a programmable option,
not a value.
2. While pressing and holding the MED TEMP
keypad with one hand, press the LOW TEMP
keypad with the other hand. The control will
revert back to the Ready Mode. Refer to Figure 2.
C762I
C783I
C848I
1 Press this pad (+) to scroll forward or increase a value
2 Press this pad (enter) to choose a selected value or
option
3 Press this pad (-) to scroll back or decrease a value
C84
8
1
32