Instruction manual

Error Codes
511210
112
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Table 13 (Continued)
Display
Information
Description
Cause/
Corrective Action
EC:22 Site Code Mismatch Incorrect card. Use card with correct site code.
EC:23 Card Maximum Value Exceeded Value on card over max. Use a card which does not exceed
maximum value.
EC:24 Insufficient Memory on Card Card memory is full. Download card contents to PC and
clear card for re-use.
EC:25 Card Reader Malfunction Faulty card reader. Replace card reader.
EC:26 Card Write Error Try card again. If error persists, card may be faulty.
EC:27 Diagnostic Test Card Write Failure Faulty card reader. Replace card reader.
EC:28 Diagnostic Test Card Read Failure Faulty card reader. Replace card reader.
EC:29 Diagnostic Test Memory Test
Failure
Faulty card reader. Replace card reader.
EC:2A Diagnostic Test Card Interface
Failure
Faulty card reader. Replace card reader.
EC:2b Diagnostic Test Flash Checksum
Failure
Faulty card reader. Replace card reader.
EC:2C Biberon or Non-biberon Device
Failure
Faulty card reader. Replace card reader.
EC:2d Firmware Update Failed, S/W
(Software) Intact
Firmware load failed. Replace card reader.
EC:2E Firmware Update Failed, S/W Not
Intact
Faulty firmware in reader. Replace card reader.
EC:2F Firmware Updated, S/W Not Intact Faulty firmware in reader. Replace card reader.
EC:30 Timeout Error Replace card reader.
EC:31 Hotlisted Card Inserted Into Reader Card hotlisted. Control will destroy card.
EC:50 Loyalty Purse Read Error Try card again. If error persists, card may be faulty.
EC:56 Loyalty Purse Write Error Try card again. If error persists, card may be faulty.
Right most DP
(decimal point)
Lit
Network Communication Error Communication problem. Wait for 1.5 minutes for error to
clear. If error doesn’t clear, power-down and power-up the
machine. If error persists, replace control or network board.
Alrm Break-in Alarm Error Service the door or coin vault switches.
OFF Break-in Alarm Shutdown Error Service the door or coin vault switches.
E:OP Open Temperature Sensor Error Open temperature sensor circuit wiring. Replace sensor.
E:SH Shorted Temperature Sensor Error Short in temperature sensor circuit wiring. Replace sensor.
Table 13 (Continued)