Testing Machine and NetMaster Functions
511210
110
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Dryer-on Temperature Test
This option tests the temperature inside the cylinder
while running a cycle. To start test, control must be in
the Testing Mode. Refer to How to Start Tests at the
beginning of this section.
To enter, press the START (enter) keypad. The VFD
display will show “XXXF” for degrees Fahrenheit or
“XXXC” for Celsius. The “XXX” will show the
degrees.
To exit the Dryer-on Temperature Test, press the MED
TEMP and LOW TEMP keypads. The control will
return to the Ready Mode. Refer to Figure 2.
Thermistor Temperature Test
This option displays the temperature sensed at the
thermistor in 5°F increments. To start test, control
must be in the Testing Mode. Refer to How to Start
Tests at the beginning of this section.
To enter, press the START (enter) keypad. The VFD
display will show “XXXF” or “XXXC” where the
“XXX” will show the degrees, the “F” will show
Fahrenheit, and the “C” will show Celsius.
To exit the Thermistor Temperature Test, press the
MED TEMP and LOW TEMP keypads. The control
will return to the Ready Mode. Refer to Figure 2.
Machine Config Display
This option shows the machine configuration values.
VFD display “+009” shows configuration value #1,
“+010” shows configuration value #2, and “+011”
shows configuration value #3. To start test, control
must be in the Testing Mode. Refer to How to Start
Tests at the beginning of this section.
To enter, press the START (enter) keypad. For
configuration value #1, the VFD will show “AXXX”.
For configuration value #2, the VFD will show “bXXX”.
For configuration value #3, the VFD will show
“CXXX”. For all, “XXX” is the value of the number.
To exit a Configuration Display Test, press the MED
TEMP and LOW TEMP keypads. The control will
return to the Ready Mode. Refer to Figure 2.