Instruction manual
Testing Machine and NetMaster Functions
109
511210
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Diagnostic Test Descriptions
Dryer Software Version
This option displays the control software version
number. To start test, control must be in the Testing
Mode. Refer to How to Start Tests at the beginning of
this section.
To enter, press the START (enter) keypad. The VFD
display will show “S:XXX” where “XXX” is the
software version number.
To exit the Dryer Software Version Number Test, press
the MED TEMP and LOW TEMP keypads. The control
will return to the Ready Mode. Refer to Figure 2.
Service Door Opening Test
This option tests the service door switch. To start test,
control must be in the Testing Mode. Refer to How to
Start Tests at the beginning of this section.
To enter, press the START (enter) keypad. The VFD
display will show “A:OO”. The “OO” will show the
number of service door openings.
The service door switch has to be closed for at least
one second and opened for at least a half a second to
make a valid count. This test will add counts to the
service door opening counter for the audit for each
opening of the test and save the date/time for the first
opening of the test.
To exit the Service Door Opening Test, press the MED
TEMP and LOW TEMP keypads. The control will
return to the Ready Mode. Refer to Figure 2.
Coin Vault Test
This option tests the coin vault switch. To start test, the
control must be in the Testing Mode. Refer to How to
Start Tests at the beginning of this section.
To enter, press the START (enter) keypad. The VFD
display will show “U:OO”. The “OO” will show the
number of coin vault openings.
The coin vault switch has to be closed for at least one
second and opened for at least a half a second to make
a valid count. This test will add counts to the coin vault
opening counter for the audit and save the time/date
for each opening of the test.
To exit the Coin Vault Test, press the MED TEMP and
LOW TEMP keypads. The control will return to the
Ready Mode. Refer to Figure 2.
Coin Drop #1 Test
This option tests coin drop #1. To start test, control
must be in the Testing Mode. Refer to How to Start
Tests at the beginning of this section.
To enter, press the START (enter) keypad. The VFD
display will show “C1:OO”. The “OO” will show the
number of coins entered. This test will add counts to
the total number of coins #1 counter. Refer to
Collecting Audit Information.
To exit the Coin Drop #1 Test, press the MED TEMP
and LOW TEMP keypads. The control will return to
the Ready Mode. Refer to Figure 2.
Coin Drop #2 Test
This option tests coin drop #2. To start test, control
must be in the Testing Mode. Refer to How to Start
Tests at the beginning of this section.
To enter, press the START (enter) keypad. The VFD
display will show “C2:OO”. The “OO” will show the
number of coins entered. This test will add counts to
the total number of coins #2 counter. Refer to
Collecting Audit Information.
To exit the Coin Drop #2 Test, press the MED TEMP
and LOW TEMP keypads. The control will return to
the Ready Mode. Refer to Figure 2.
Start Pulse Test
This option tests the Start Pulse. To start test, control
must be in the Testing Mode. Refer to How to Start
Tests at the beginning of this section.
To enter, press the START (enter) keypad. The VFD
display will show “St:OO”. The “OO” will show the
number of pulses entered. This test will add counts to
the total number of Start Pulses counter. Refer to
Collecting Audit Information.
To exit the Start Pulse Test, press the MED TEMP and
LOW TEMP keypads. The control will return to the
Ready Mode. Refer to Figure 2.