Instruction manual

511210
108
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Testing Machine and NetMaster Functions
This feature allows the owner to run diagnostic tests
on various dryer operations without servicing the
dryer. The following tests are available:
Dryer Software Version
Service Door Opening Test
Coin Vault Test
Coin Drop #1 Test
Coin Drop #2 Test
Start Pulse Test
Dryer-on Temperature Test
Thermistor Temperature Test
Configuration Display Test
How to Enter Testing Feature
1. Control must be in Manual Mode. Refer to
Entering the Manual Mode.
2. Press the LOW TEMP (+) or the NO HEAT (-)
keypad until “dIAg” appears.
3. Press the START (enter) keypad. Display will
change to “+001” indicating the dryer software
version number test.
4. Press the LOW TEMP (+) or the NO HEAT (-)
keypad to scroll through the diagnostic test
options.
How to Start Tests
To start a diagnostic test, refer to the quick reference
table below (Tabl e 12 ). Press the START (enter)
keypad when the desired test # is displayed. For detailed
information on each test, read the appropriate description.
How to Exit Testing Feature
While pressing and holding the MED TEMP keypad
with one hand, press the LOW TEMP keypad with the
other hand. The display will return to the Ready Mode.
Refer to Figure 2.
Diagnostic (Testing) Mode – Quick Reference Table
Diagnostic Mode VFD Display Prior to Entry VFD Display upon Test Entry
Dryer Software Version +001
S:XXX
Service Door Opening Test +002
A:OO
Coin Vault Test +003
U:OO
Coin Drop #1 Test +004
C1:OO
Coin Drop #2 Test +005
C2:OO
Start Pulse Test +006
St:OO
Dryer-on Temperature Test +007
F- - - or C- - -
Thermistor Temperature Test +008
FXXX or CXXX
Machine Config #1 Display +009
AXXX
Machine Config #2 Display +010
bXXX
Machine Config #3 Display +011
CXXX
Table 12