Washer Extractors HF455, HF575, HF730, HF900 for corresponding “CHF” and “IHF” models, see page 5 for complete model list Instruction manual Technical specifications Installation instructions Maintenance Part No.
Contents 1 Model Numbers ............................................................................................... 5 2 Safety and Environmental Informations ....................................................... 6 Safety ........................................................................................................... 6 Environmental ............................................................................................... 7 Explanation of Safety Messages ...............................
5 Steam connection ......................................................................................... 38 6 Technical remarks ........................................................................................ 39 Internal connections of the electrical heating ............................................. 39 Out of balance switch ................................................................................. 40 Opening the door in case of an emergency ............................................
1 Model Numbers Build-up xHF455 xHF575 xHF730 xHF900 xHF100yyHyyyyyy xHF135yyHyyyyyy xHF165yyHyyyyyy xHF455yyHyyyyyy xHF575yyHyyyyyy xHF730yyHyyyyyy xHF900yyHyyyyyy Model numbers IHF100ANH IHF900MNH IHF100MNH IHF900ZNH IHF135ANH CHF100ANH IHF135MNH CHF100MNH IHF165ANH CHF135ANH IHF165MNH CHF135MNH IHF455ANH CHF165ANH IHF455MNH CHF165MNH IHF455ZNH CHF455ANH IHF575ANH CHF455MNH IHF575MNH CHF575ANH IHF575ZNH CHF575MNH IHF730ANH CHF730ANH IHF730MNH CHF730MNH IHF730ZNH CHF900ANH
2 Safety and Environmental Informations Safety CAUTION LABELS Please familiarize yourself with the following standard warning symbols. They are used throughout this manual and on the equipment to alert you to possible hazards. Anyone operating or servicing this equipment must understand these symbols and must follow all safety rules in this manual. ELECTRICAL HAZARD This symbol alerts you to the presence of a dangerous voltage, which could cause a serious shock resulting in personal injury or death.
2 Environmental Disposal of Unit This appliance is marked according to the European directive 2002/96/ EC on Waste Electrical and Electronic Equipment (WEEE). This symbol on the product or on its packaging indicates that this product shall not be treated as household waste. Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment.
2 Explanation of Safety Messages Throughout this manual and on machine decals, you will find precautionary statements (“DANGER,” “WARNING,” and “CAUTION”) followed by specific instructions. These precautions are intended for the personal safety of the operator, user, servicer, and those maintaining the machine. DANGER Indicates an imminently hazardous situation that, if not avoided, will cause severe personal injury or death.
2 Important Safety Instructions WARNING To reduce the risk of fire, electric shock, serious injury or death to persons when using your washer, follow these basic precautions: 1. Read all instructions before using the washer. 2. Refer to the GROUNDING INSTRUCTIONS in the installation Manual for the proper grounding of the washer. 3.
2 21. Loading door MUST BE CLOSED any time the washer is to fill, tumble, or spin. DO NOT bypass the loading door switch by permitting the washer to operate with the loading door open. 22. Always read and follow manufacturer’s instructions on packages of laundry and cleaning aids. Heed all warnings or precautions. To reduce the risk of poisoning or chemical burns, keep them out of the reach of children at all times (preferably in a locked cabinet). 23.
2 Operator Safety WARNING NEVER insert hands or objects into basket until it has completely stopped. Doing so could result in serious injury. To ensure the safety of machine operators, the following maintenance checks must be performed daily: 1. Prior to operating the machine, verify that all warning signs are present and legible. Missing or illegible signs must be replaced immediately. Make certain that spares are available. 2. Check door interlock before starting operation of the machine: a.
3 Technical data and dimensions Technical data HF455, IHF455, IHF100, CHF100 METRIC US Capacity (dry weight) Ratio [kg/Lit] 1:11 41,4 kg 91.27 lb. 1:10 45,5 kg 100.31 lb. 1:9 50,5 kg 111.33 lb. Diameter 980 mm 38.58 inch Depth 597 mm 23.50 inch Volume 455 Lit 16.07 ft³ Height 1920 mm 75.59 inch Width 1200 mm 47.24 inch Depth 1340 mm 52.76 inch Diameter door opening 500 mm 19.69 inch Height under door 638 mm 25.12 inch To center 960 mm 37.
3 Dimensions HF455, IHF455, IHF100, CHF100 Legend: metric mm [inches] 638 [25.12] 962 [37.87] 1920 [75.59] 56.5 [2.23] 83 [3.27] 1034 [40.71] 83 [3.27] 1200 [47.24] 45 [1.77] 156.5 [6.16] 1010 [39.76] 45 [1.77] 1100 [43.31] 26.5 [1.04] 1283 [50.51] 303 [11.93] 113 [4.45] C A B 257 [10.12] 173 [6.81] E A 162 [6.38] 102 [4.02] F G G 83 [3.27] I A. Soft water connection 3/4" B. Warm water connection 3/4" C. Hard water connection 3/4" D.
3 Technical data HF575, IHF575, IHF135, CHF135 METRIC US Capacity (dry weight) Ratio [kg/Lit] 1:11 52,3 kg 115.30 lb. 1:10 57,5 kg 126.77 lb. 1:9 63,8 kg 140.65 lb. Diameter 980 mm 38.58 inch Depth 775 mm 30.51 inch Volume 575 Lit 20.31 ft³ Height 1920 mm 75.59 inch Width 1200 mm 47.24 inch Depth 1510 mm 59.45 inch Diameter door opening 500 mm 19.69 inch Height under door 638 mm 25.12 inch To center 960 mm 37.
3 Dimensions HF575, IHF575, IHF135, CHF135 Legend: metric mm [inches] 638 [25.12] 962 [37.87] 1920 [75.59] 56.5 [2.23] 83 [3.27] 1034 [40.71] 83 [3.27] 45 [1.77] 1180 [46.46] 155.5 [6.12] 1200 [47.24] 45 [1.77] 1270 [50] 26.5 [1.04] 1452 [57.17] 303 [11.93] 113 [4.45] C A B 257 [10.12] 173 [6.81] E A 162 [6.38] 102 [4.02] F G G 83 [3.27] I A. Soft water connection 3/4" B. Warm water connection 3/4" C. Hard water connection 3/4" D. Electrical connection E.
3 Technical data HF730, IHF730, IHF165, CHF165 METRIC US 1:11 66,4 kg 146.39 lb. 1:10 73 kg 160.94 lb. 1:9 81,1 kg 178.79 lb. Capacity (dry weight) Ratio [kg/Lit] Cylinder Diameter 1095 mm 43.11 inch Depth 775 mm 30.51 inch Volume 730 Lit 25.78 ft³ Height 2100 mm 82.68 inch Width 1300 mm 51.18 inch Depth 1628 mm 64.09 inch Diameter door opening 622 mm 24.49 inch 603 mm 23.74 inch 992,5 mm 39.
3 Dimensions HF730, IHF730, IHF165, CHF165 Legend: metric mm [inches] 603 [23.74] 992.5 [39.07] 2100 [82.68] 56.5 [2.23] 81 [3.19] 1138 [44.8] 81 [3.19] 1300 [51.18] 44 [1.73] 1185 [46.65] 272 [10.71] 1273 [50.12] 44 [1.73] 26.5 [1.04] 1571.5 [61.87] 408 [16.06] 173 [6.81] D A C 257 [10.12] 248 [9.76] F 117 [4.61] E I G H E 81 [3.19] J A. Soft water connection 3/4" B. Soft water connection 1" C. Warm water connection 1" D. Hard water connection 1" E.
3 Technical data HF900, IHF900 METRIC US 1:11 81,8 kg 180.34 lb. 1:10 90 kg 198.42 lb. 1:9 100 kg 220.46 lb. Capacity (dry weight) Ratio [kg/Lit] Cylinder Diameter 1095 mm 43.11 inch Depth 957 mm 37.68 inch Volume 900 Lit 31.78 ft³ Height 2100 mm 82.68 inch Width 1300 mm 51.18 inch Depth 1808 mm 71.18 inch Diameter door opening 622 mm 24.49 inch 603 mm 23.74 inch 992,5 mm 39.
3 Dimensions HF900, IHF900 Legend: metric mm [inches] 603 [23.74] 992.5 [39.07] 2100 [82.68] 56.5 [2.23] 81 [3.19] 1138 [44.8] 81 [3.19] 1300 [51.18] 44 [1.73] 1365 [53.74] 272 [10.71] 1453 [57.2] 44 [1.73] 26.5 [1.04] 1751.5 [68.96] 408 [16.06] 173 [6.81] D A C 257 [10.12] 248 [9.76] F 117 [4.61] E I G H E 81 [3.19] J A. Soft water connection 3/4" B. Soft water connection 1" C. Warm water connection 1" D. Hard water connection 1" E.
4 Installation and Connection Instructions CAUTION Ensure that the machine is installed on a level floor of sufficient strength and that the recommended clearances for inspection and maintenance are provided. Never allow the inspection and maintenance space to be blocked. Surface Label 1 The machine must be placed on a flat, solid surface (metal base, concrete or solid ground).
4 Mounting Bolt Hole Locations for machines, HF455, IHF455, IHF100, CHF100 45 [1.77] Legend: metric mm [inches] 0[ Ø0 .7 9] Ø2 0[ Ø0 .7 Ø2 9] 1010 [39.76] 1100 [43.31] 9] Ø2 0[ .7 Ø0 45 [1.77] Ø2 0[ ] .79 Ø0 83 [3.27] 1034 [40.71] 83 [3.27] 1200 [47.
4 Mounting Bolt Hole Locations for machines, HF575, IHF575, IHF135, CHF135 0[ Ø0 .7 Ø2 9] 45 [1.77] Legend: metric mm [inches] 20 Ø0 .7 Ø 9] 1180 [46.46] 1270 [50] 9] Ø2 0[ .7 Ø0 45 [1.77] ] Ø2 0[ 79 0. [Ø 83 [3.27] 1034 [40.71] 83 [3.27] 1200 [47.
4 Mounting Bolt Hole Locations for machines, HF730, IHF730, IHF165, CHF165 44 [1.73] Legend: metric mm [inches] 0 Ø0 .7 9] Ø2 44 [1.73] 9] Ø2 .7 Ø0 0[ 0[ Ø0 .7 Ø2 9] 1185 [46.65] 1273 [50.12] ] Ø2 0[ 79 0. [Ø 81 [3.19] 1138 [44.8] 81 [3.19] 1300 [51.
4 Mounting Bolt Hole Locations for machines, HF900, IHF900 Ø2 0. 79 ] 44 [1.73] Legend: metric mm [inches] Ø2 20 0[ Ø0 Ø .79 ] 1365 [53.74] 1453 [57.2] ] .79 0 Ø0 [Ø 0[ 44 [1.73] Ø2 ] 79 0. [Ø 81 [3.19] 1138 [44.8] 81 [3.19] 1300 [51.
4 Water connection The machine is delivered with hoses with 3/4" connections (HF455-575) and with 1x3/4" + 3x1" connections (HF730-900). These hoses fit the water inlet valves of the machine and the main water inlet taps. All the inlet valves have to be connected. To ensure the optimal functioning of the water inlet valves, the water pressure on the inlet should be between 3 and 5 bar (40 and 80 psi). If the pressure is too low, the cycle time will increase considerably.
4 Electrical Installation Important Electrical ratings are subject to changes. Refer to serial plate decal for electrical ratings information specific to your machine. WARNING Hazardous Voltage. Can cause shock, burn or cause death. Allow machine power to remain off for two minutes prior to working in and around AC inverter drive. WARNING Hazardous Voltage. Can cause shock, burn or death.
4 Use wire sizes indicated in Table 2 through 5 for runs up to 50 feet. Use next larger size for runs of 50 to 100 feet. Use two sizes larger for runs greater than 100 feet. For personal safety and proper operation, the washer-extractor must be grounded in accordance with state and local standards. If such standards are not available, grounding must conform to the National Electric Code, article 250-95.
4 Main power connection Label 3 Connection label: Machine power connections are made at the back of the machine. Three or four conductor power cable is the recommended method (See chapter electrical specs for minimum cable requirements, if local electrical codes exceed these requirements, follow local codes). The number of conductors in this cable and the proper connection points for the cable wires shall be determined by the machine and power requirements.
4 200-240 Volts, 3-Phase, 3-wire + PE, 50 or 60 Hertz Configuration (Named: Q-Voltage or 3-phase X-Voltage): With supply power of: 200-240 Volts, 3-phase, 3-wire, after connecting the green/yellow PE ground wire, connect one power wire to each of the terminals at the bottom of the power contactor switch marked: “L1,L2,L3”.
4 WARNING The washer-extractor should be connected to an individual branch circuit not shared with lighting or other equipment. Electrical Specifications HF455, IHF455, IHF100, CHF100 455 liters / 100 pounds Boiler Fed/Steam Heat 22 30 32 10/6.0 P 380-415 50/60 3 3+N+PE 22 30 32 10/6.0 Q 200-240 50/60 3 3+PE 36 40 40 8/10.
4 WARNING The washer-extractor should be connected to an individual branch circuit not shared with lighting or other equipment. Electrical Specifications HF575, IHF575, IHF135, CHF135 575 liters / 135 pounds Boiler Fed/Steam Heat 27 30 32 10/6.0 P 380-415 50/60 3 3+N+PE 27 30 32 10/6.0 Q 200-240 50/60 3 3+PE 52 60 60 8/10.
4 WARNING The washer-extractor should be connected to an individual branch circuit not shared with lighting or other equipment. Electrical Specifications HF730, IHF730, IHF165, CHF165 730 liters / 165 pounds Boiler Fed/Steam Heat 3 3+PE 44 50 50 8/10.0 50/60 3 3+N+PE 44 50 50 8/10.0 Q 200-240 50/60 3 3+PE 85 90 90 4/25.
4 WARNING The washer-extractor should be connected to an individual branch circuit not shared with lighting or other equipment. Electrical Specifications HF900, IHF900 900 liters / 200 pounds Boiler Fed/Steam Heat 44 50 50 8/10.0 P 380-415 50/60 3 3+N+PE 44 50 50 8/10.0 Q 200-240 50/60 3 3+PE 85 90 90 4/25.
4 Automatic lubricator The bearing house of the machine is equipped with a lubricating device (A) which automatically lubricates the bearing during one year. Upon delivery of the machine, this lubricator has not been brought into use. To this effect, please put on the matching screw (B) in the foreseen opening of the lubricator. (See Label 4) Ignoring this instruction will inevitably cause damage to the bearings! Warranty is void if bearings are not lubricated.
4 Liquid soap connection (option) Connection of the liquid soap hoses The liquid soap connection consists of 8 connections for liquid soap (See Label 5). The central opening is used for ventilation. WARNING Label 5 Dangerous Chemicals. May damage eyes and skin. Wear eye and hand protection when handling chemicals; always avoid direct contact with raw chemicals. Read the manufacturer’s directions for accidental contact before handling chemicals.
4 The 220V can be transformed to other values to drive other type soap pumps. Example: pumps 24V ~. (See Label 7) Label 7 Also, pumps with different operating tension can be combined. Example: 5 pumps 220V ~ and 1 pump 24V ~.
4 Connection of a central operating panel for coin machines (option) WARNING To reduce the risk of electric shock, disconnect this appliance from the power supply before attempting any user maintenance. Turning the controls to the OFF position does not disconnect this appliance from the power supply. At the backside above the main connectors, you find a printboard, to which the central operating panel for coin machines can be connected.
5 Steam connection WARNING Never touch internal or external steam pipes, connections, or components. These surfaces can be extremely hot and will cause severe burns. The steam must be turned off and the pipe, connections, and components allowed to cool before the pipe can be touched. Machines with steam heating must have a steam valve between the steam installation and the machine. 5 3 4 3 2 1 6 7 With direct steam injection into the machine (See Table 6) 1. Steam pipe 2. Steam cut-off valve 3.
6 Technical remarks Internal connections of the electrical heating 1 AC Heating 3kw R5 LC1D0901 Table 7 3 AC Heating 3x230V R5 3x400V R5 4,2kw 3x1,4kw See Label 14 LC1D0901 See Label 15 LC1D0901 6kw 3x2kw See Label 14 LC1D0901 See Label 15 LC1D0901 9kw 3x3kw See Label 14 LC1D1810 See Label 15 LC1D0901 12kw 3x4kw -------- See Label 14 LC1D0901 12kw 3x2kw 3x2kw See Label 14 See Label 14 LC1D1810 LC1D1810 See Label 15 LC1D1810 15kw 3x2kw 3x3kw See Label 14 See Label 14
6 Out of balance switch 1/2 The out of balance switch is mounted on the solid part of the machine. There is a window around the probe of the out of balance switch that is mounted on the movable part of the machine. When the machine goes out of balance by overloading or uneven distribution of the linen, the out of balance switch will interrupt this action to prevent damage to the machine.
7 Maintenance instruction of the machine WARNING To reduce the risk of electric shock, disconnect this appliance from the power supply before attempting any user maintenance. Turning the controls to the OFF position does not disconnect this appliance from the power supply. Before starting wiring or inspection, power must be switched OFF, check to make sure that the operation panel indicator is off.
7 Annual maintenance Belt tension: Verify that the belts are running in the middle of the basket pulley. Verify the belt tension according to the table below. Belt tension measurements should be taken as close as possible to the center of the belt span (see figure).
8 Contact Information Nameplate Nameplate Location The nameplate is located at the rear of the machine. Always provide the machine’s serial number and model number when ordering parts or when seeking technical assistance. See Labels 17 and 18.
8 Position of the Serial plate Replacement Parts If literature or replacement parts are required, contact the source from which the machine was purchased or contact the phone numbers or websites shown on the nameplate.
9 Repair and after-sales service In case of important malfunctions and deficiencies, which you cannot resolve yourself, contact your distributor. Distributor : Name:..................................................................................... Address:................................................................................. Tel.:......................................................................................... Machine : Type:.......................................................