Washer Extractors HF150, HF185, HF234, HF304 for corresponding “CHF” and “IHF” models, see page 5 for complete model list Instruction manual Technical specifications Installation instructions Maintenance Part No.
Contents 1 Model Numbers ............................................................................................... 5 2 Safety and Environmental Informations ....................................................... 6 Safety ........................................................................................................... 6 Environmental ............................................................................................... 7 Explanation of Safety Messages ...............................
5 Steam connection ......................................................................................... 38 6 Technical remarks ........................................................................................ 39 Internal connections of the electrical heating ............................................. 39 7 Maintenance instruction of the machine .................................................... 40 End of day ....................................................................................
1 Model Numbers Build-up HF150 HF185 HF234 HF304 HX55 HX75 xHF150yyHyyyyyy xHF185yyHyyyyyy xHF234yyHyyyyyy xHF304yyHyyyyyy xHF033yyHyyyyyy xHF045yyHyyyyyy xHF055yyHyyyyyy xHF075yyHyyyyyy Model numbers CHF033 IHF150MNHX1 CHF045 IHF150ZNHP1 CHF055 IHF185 CHF055ANHX1 IHF185ANHN1 CHF055MNHX1 IHF185ANHP1 CHF075 IHF185ANHX1 CHF075ANHP1 IHF185YNHP1 CHF075ANHQ1 IHF185ZNHP1 CHF150 IHF185ZNHX1 CHF185 IHF234 CHF234 IHF234ANHN1 CHF304 IHF234ANHP1 IHF033 IHF234ANHQ1 IHF033ANHX1 IHF234MNHP1
2 Safety and Environmental Informations Safety CAUTION LABELS Please familiarize yourself with the following standard warning symbols. They are used throughout this manual and on the equipment to alert you to possible hazards. Anyone operating or servicing this equipment must understand these symbols and must follow all safety rules in this manual. ELECTRICAL HAZARD This symbol alerts you to the presence of a dangerous voltage, which could cause a serious shock resulting in personal injury or death.
2 Environmental Disposal of Unit This appliance is marked according to the European directive 2002/96/EC on Waste Electrical and Electronic Equipment (WEEE). This symbol on the product or on its packaging indicates that this product shall not be treated as household waste. Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment.
2 Explanation of Safety Messages Throughout this manual and on machine decals, you will find precautionary statements (“DANGER”, “WARNING” and “CAUTION”) followed by specific instructions. These precautions are intended for the personal safety of the operator, user, servicer, and those maintaining the machine. DANGER Indicates an imminently hazardous situation that, if not avoided, will cause severe personal injury or death.
2 Important Safety Instructions WARNING To reduce the risk of fire, electric shock, serious injury or death to persons when using your washer, follow these basic precautions: 1. Read all instructions before using the washer. 2. Refer to the GROUNDING INSTRUCTIONS in the installation Manual for the proper grounding of the washer. 3.
2 21. Loading door MUST BE CLOSED any time the washer is to fill, tumble, or spin. DO NOT bypass the loading door switch by permitting the washer to operate with the loading door open. 22. Always read and follow manufacturer’s instructions on packages of laundry and cleaning aids. Heed all warnings or precautions. To reduce the risk of poisoning or chemical burns, keep them out of the reach of children at all times (preferably in a locked cabinet). 23.
2 Operator Safety WARNING NEVER insert hands or objects into basket until it has completely stopped. Doing so could result in serious injury. To ensure the safety of machine operators, the following maintenance checks must be performed daily: 1. Prior to operating the machine, verify that all warning signs are present and legible. Missing or illegible signs must be replaced immediately. Make certain that spares are available. 2. Check door interlock before starting operation of the machine: a.
3 Technical data and dimensions Technical data HF150, IHF150, IHF033, CHF150, CHF033 METRIC US 1:11 13,2 kg 29.10 lb. 1:10 14,5 kg 31.97 lb. 1:9 16,1 kg 35.49 lb. Diameter 680 mm 26.77 inch Depth Capacity (dry weight) Ratio [kg/Lit] Cylinder 400 mm 15.75 inch Volume 145 Lit 5.12 ft³ Height 1376 mm 54.15 inch Width 780 mm 30.71 inch Depth 840 mm 33.07 inch Diameter door opening 400 mm 15.75 inch Height under door 472 mm 18.58 inch To center 745 mm 29.
3 Dimensions HF150, IHF150, IHF033, CHF150, CHF033 Legend: metric mm [inches] 472 [18.58] 1376 [54.15] 220 [8.66] 1348 [53.07] 88 [3.47] 50 [1.97] 680 [26.77] 50 [1.97] 34 [1.34] 665 [26.18] 780 [30.71] 34 [1.34] 733 [28.86] 86.5 [3.41] 753 [29.65] 332 [13.05] 267 [10.49] 202 [7.93] 105 [4.13] A F D B C E G I 109 [4.3] 35 [1.38] 704 [27.7] 1015 [39.96] 1066 [41.95] A. Ventilation soap dispenser B. Liquid soap connections C. Hard water connections 3/4" D.
3 Technical data HF185, IHF185, IHF045, CHF185, CHF045 METRIC US 1:11 16,5 kg 36.38 lb. 1:10 18,1 kg 39.90 lb. 1:9 20,1 kg 44.31 lb. Diameter 680 mm 26.77 inch Depth Capacity (dry weight) Ratio [kg/Lit] Cylinder 500 mm 19.69 inch Volume 181 Lit 6.39 ft³ Height 1376 mm 54.15 inch Width 780 mm 30.71 inch Depth 940 mm 37.01 inch Diameter door opening 400 mm 15.75 inch Height under door 472 mm 18.58 inch To center 745 mm 29.
3 Dimensions HF185, IHF185, IHF045, CHF185, CHF045 Legend: metric mm [inches] 472 [18.58] 1376 [54.15] 220 [8.66] 1348 [53.07] 88 [3.47] 50 [1.97] 680 [26.77] 50 [1.97] 34 [1.34] 765 [30.12] 34 [1.34] 833 [32.8] 780 [30.71] 86.5 [3.41] 853 [33.58] 332 [13.05] 267 [10.49] 202 [7.93] 105 [4.13] A F D B C E G I 109 [4.3] 35 [1.38] 704 [27.7] 1015 [39.96] 1066 [41.95] A. Ventilation soap dispenser B. Liquid soap connections C. Hard water connections 3/4" D.
3 Technical data HF234, IHF234, IHF055, CHF234, CHF055 METRIC US 1:11 21,3 kg 46.96 lb. 1:10 23,4 kg 51.59 lb. 1:9 26 kg 57.32 lb. Diameter 750 mm 29.53 inch Depth 530 mm 20.87 inch Volume 234 Lit 8.26 ft³ Height 1528 mm 60.14 inch Width 900 mm 35.43 inch Depth 996 mm 39.21 inch Diameter door opening 400 mm 15.75 inch Height under door 533 mm 20.96 inch To center 805 mm 31.
3 Dimensions HF234, IHF234, IHF055, CHF234, CHF055 Legend: metric mm [inches] 65 [2.56] 240 [9.45] H 533 [20.96] 1528 [60.14] 1500 [59.05] H 81 [3.19] 738 [29.05] 81 [3.19] 900 [35.43] 35 [1.38] 830 [32.68] 35 [1.38] 900 [35.43] 70 [2.76] 926 [36.46] 346 [13.62] 251 [9.88] 156 [6.12] A C E D F B I G 116 [4.57] 720 [28.35] 1126.9 [44.36] 1266 [49.82] A. Ventilation soap dispenser B. Liquid soap connections C. Hard water connections 3/4" D. Warm water connections 3/4" E.
3 Technical data HF304, IHF304, IHF075, CHF304, CHF075 METRIC US 1:11 27,6 kg 60.85 lb. 1:10 30,4 kg 67.02 lb. 1:9 33,7 kg 74.30 lb. Diameter 850 mm 33.46 inch Depth 537 mm 21.14 inch Volume 304 Lit 10.74 ft³ Height 1558 mm 61.32 inch Width 1060 mm 41.73 inch Depth 1147 mm 45.16 inch Diameter door opening 400 mm 15.75 inch Height under door 567 mm 22.32 inch To center 845 mm 33.
3 Dimensions HF304, IHF304, IHF075, CHF304, CHF075 Legend: metric mm [inches] 245 [9.65] H H 567 [22.32] 1558 [61.32] 1530 [60.24] 71.5 [2.81] 97.5 [3.84] 865 [34.06] 97.5 [3.84] 1060 [41.73] 40 [1.57] 960 [37.8] 40 [1.57] 1040 [40.94] 82 [3.23] 488 [19.21] 1065 [41.93] 367.5 [14.47] 247 [9.72] 187 [7.36] A C D E F B G 1167 [45.93] 35 [1.38] L A. Ventilation soap dispenser B. Liquid soap connections C. Hard water connections 3/4" D.
4 Installation and Connection Instructions CAUTION Ensure that the machine is installed on a level floor of sufficient strength and that the recommended clearances for inspection and maintenance are provided. Never allow the inspection and maintenance space to be blocked. Surface The machine must be placed on a flat, solid surface (metal base, concrete or solid ground).
4 Removal of the transport safety HF234-304 To prevent damage during transportation, the machine has been equipped with four red transport brackets to eliminate every possible movement of the tub. After the machine has been placed level, take off the service panel and back panel to remove these transport brackets. (See Labels 3 and 4) Important The machine must never be activated before removing these transport brackets.
4 Mounting Bolt Hole Locations for machines, HF150, IHF150, IHF033, CHF150, CHF033 Legend: metric mm [inches] 34 [1.34] 665 [26.18] ] 87 0. [Ø 680 [26.77] 50 [1.97] 780 [30.71] 22 733 [28.86] 22 34 [1.34] Ø 50 [1.
4 Mounting Bolt Hole Locations for machines, HF185, IHF185, IHF045, CHF185, CHF045 [Ø 0. 87 ] 34 [1.34] 50 [1.97] 680 [26.77] 50 [1.97] 780 [30.71] 23 833 [32.8] 22 765 [30.12] Ø 34 [1.
4 Mounting Bolt Hole Locations for machines, HF234, IHF234, IHF055, CHF234, CHF055 Legend: metric mm [inches] 35 [1.38] 830 [32.68] ] 87 0. [Ø 738 [29.05] 81 [3.19] 900 [35.43] 24 900 [35.43] 22 35 [1.38] Ø 81 [3.
4 Mounting Bolt Hole Locations for machines, HF304, IHF304, IHF075, CHF304, CHF075 40 [1.57] Legend: metric mm [inches] Ø 22 40 [1.57] 865 [34.06] 97.5 [3.84] 1060 [41.73] 25 1040 [40.94] 960 [37.8] ] 87 0. [Ø 97.5 [3.
4 Water connection The machine is delivered with hoses with 3/4" connections. These hoses fit the water inlet valves of the machine and the main water inlet taps. All the inlet valves have to be connected. To ensure the optimal functioning of the water inlet valves, the water pressure on the inlet should be between 3 and 5 bar (40 and 80 psi). If the pressure is too low, the cycle time will increase considerably.
4 Electrical installation Important Electrical ratings are subject to changes. Refer to serial plate decal for electrical ratings information specific to your machine. WARNING Hazardous Voltage. Can cause shock, burn or cause death. Allow machine power to remain off for two minutes prior to working in and around AC inverter drive. WARNING Hazardous Voltage. Can cause shock, burn or death.
4 Use wire sizes indicated in Table 3 through 6 for runs up to 50 feet. Use next larger size for runs of 50 to 100 feet. Use two sizes larger for runs greater than 100 feet. For personal safety and proper operation, the washer-extractor must be grounded in accordance with state and local standards. If such standards are not available, grounding must conform to the National Electric Code, article 250.
4 Main power connection Label 5 Connection label: Machine power connections are made at the back of the machine. Three or four conductor power cable is the recommended method (See chapter electrical specs for minimum cable requirements, if local electrical codes exceed these requirements, follow local codes). The number of conductors in this cable and the proper connection points for the cable wires shall be determined by the machine and power requirements.
4 200-240 Volts, 3-Phase, 3-wire + PE, 50 or 60 Hertz Configuration (Named: Q-Voltage or 3-phase X-Voltage): With supply power of: 200-240 Volts, 3-phase, 3-wire, after connecting the green/yellow PE ground wire, connect one power wire to each of the terminals at the bottom of the power contactor switch marked: “L1,L2,L3”.
4 WARNING The washer-extractor should be connected to an individual branch circuit not shared with lighting or other equipment. Electrical Specifications HF150, IHF150, IHF033, CHF150, CHF033 150 liters / 33 pounds Boiler Fed/Steam Heat 6 15 10 14/2.5 P 380-415 50/60 3 3+N+PE 18 20 20 12/4.0 Q 200-240 50/60 3 3+PE 18 20 20 12/4.0 X 200-240 50/60 1/3 2/3+PE 18 20 20 12/4.
4 WARNING The washer-extractor should be connected to an individual branch circuit not shared with lighting or other equipment. Electrical Specifications HF185, IHF185, IHF045, CHF185, CHF045 185 liters / 45 pounds Boiler Fed/Steam Heat 6 15 10 14/2.5 P 380-415 50/60 3 3+N+PE 18 20 20 12/4.0 Q 200-240 50/60 3 3+PE 18 20 20 12/4.0 X 200-240 50/60 1/3 2/3+PE 18 20 20 12/4.
4 WARNING The washer-extractor should be connected to an individual branch circuit not shared with lighting or other equipment.
4 WARNING The washer-extractor should be connected to an individual branch circuit not shared with lighting or other equipment.
4 Liquid soap connection (option) Connection of the liquid soap hoses The liquid soap connection consists of 8 connections for liquid soap (See Label 6). The central opening is used for ventilation. WARNING Label 6 Dangerous Chemicals. May damage eyes and skin. Wear eye and hand protection when handling chemicals; always avoid direct contact with raw chemicals. Read the manufacturer’s directions for accidental contact before handling chemicals.
4 The 220V can be transformed to other values to drive other type soap pumps. Example: pumps 24V ~. (See Label 8) Label 8 Also, pumps with different operating tension can be combined. Example: 5 pumps 220V ~ and 1 pump 24V ~.
4 Connection of a central operating panel for coin machines (option) WARNING To reduce the risk of electric shock, disconnect this appliance from the power supply before attempting any user maintenance. Turning the controls to the OFF position does not disconnect this appliance from the power supply. At the backside above the main connectors, you find a printboard, to which the central operating panel for coin machines can be connected.
5 Steam connection WARNING Never touch internal or external steam pipes, connections, or components. These surfaces can be extremely hot and will cause severe burns. The steam must be turned off and the pipe, connections, and components allowed to cool before the pipe can be touched. Machines with steam heating must have a steam valve between the steam installation and the machine. 5 3 4 3 2 1 6 7 With direct steam injection into the machine (See Table 7) 1. Steam pipe 2. Steam cut-off valve 3.
6 Technical remarks Internal connections of the electrical heating 1 AC Heating 3kw R5 LC1D0901 Table 8 3 AC Heating 3x230V R5 3x400V R5 4,2kw 3x1,4kw See Label 15 LC1D0901 See Label 16 LC1D0901 6kw 3x2kw See Label 15 LC1D0901 See Label 16 LC1D0901 9kw 3x3kw See Label 15 LC1D1810 See Label 16 LC1D0901 12kw 3x4kw -------- -------- See Label 15 LC1D0901 12kw 3x2kw 3x2kw See Label 15 See Label 15 LC1D1810 LC1D1810 See Label 16 LC1D1810 15kw 3x2kw 3x3kw See Label 15 See
7 Maintenance instruction of the machine WARNING To reduce the risk of electric shock, disconnect this appliance from the power supply before attempting any user maintenance. Turning the controls to the OFF position does not disconnect this appliance from the power supply. Before starting wiring or inspection, power must be switched OFF, check to make sure that the operation panel indicator is off.
7 Annual maintenance Belt tension: Verify that the belts are running in the middle of the basket pulley. Verify the belt tension according to the table below. Belt tension measurements should be taken as close as possible to the center of the belt span (see figure).
8 Contact Information Nameplate Nameplate Location The nameplate is located at the rear of the machine. Always provide the machine’s serial number and model number when ordering parts or when seeking technical assistance. See Labels 17 and 18.
8 Position of the Serial plate Replacement Parts If literature or replacement parts are required, contact the source from which the machine was purchased or contact the phone numbers or websites shown on the nameplate.
9 Repair and after-sales service In case of important malfunctions and deficiencies, which you cannot resolve yourself, contact your distributor. Distributor : Name:..................................................................................... Address:................................................................................. Tel.:......................................................................................... Machine : Type:.......................................................